RSP3-6
Probe attributes
2-axis scanning (X,Y) and 3-axis touch-trigger (X,Y,Z)
Measurement range
±0.5 mm deflection in all directions in all orientations
Overtravel range
X, Y
2 mm
+Z
1.7 mm
-Z
1.2 mm
Resolution
Capable of <0.1 μm
Weight
300 g (10.58 oz) (excluding stylus holder and stylus)
Effective stylus length range
RSP3-6 + RSH3-6c-500
EWL 348 mm (13.70 in) using M2 star centre
RSP3-6 + RSH3-6c-600
EWL 448 mm (17.64 in) using M2 star centre
RSP3-6 + RSH3-6-600
EWL 456 mm (17.95 in) using 10 mm stylus
RSP3-6 + RSH3-6-700
EWL 556 mm (21.89 in) using 10 mm stylus
RSP3-6 + RSH3-6-800
EWL 656 mm (25.83 in) using 10 mm stylus
Mounting
Magnetised kinematic coupling
Crash protection
±X, ±Y, ‐Z
Via break out of probe or stylus holder
+Z
Via integral bump-stop design
Change rack options
RCP TC-3
Thermally controlled change port for probe changing only
This single port unit mounts on the MRS / MRS2 rack
RCP2
For stylus holder changing only
This single port unit mounts to the MRS or MRS2
Interface options
UCC S5
RSP3 installation and user's guide
www.renishaw.com
Issued 06 2022
19