3.7
System installation
± 10 µm
Stylus on-centre adjustment
1
2
3
NOTES:
During adjustment, care must be taken not to rotate the probe relative to the shank, as damage to the
bobbin (A-4038-0303) can occur where fitted.
If a probe and shank assembly is dropped, it must be rechecked for correct on-centre adjustment.
Do not hit or tap the probe to achieve on-centre adjustment.
× 4
± 10 µm
± 2.5 µm
1.5 Nm
– 3.2 Nm
(1.1 lbf.ft –
2.4 lbf.ft)
× 4
6 Nm – 8 Nm
× 2