7.3
Fault-finding
Symptom
Cause
Action
Poor probe repeatability
and/or accuracy.
Debris on part or stylus.
Clean part and stylus.
Poor tool change repeatability.
Redatum probe after each tool
change.
Loose probe mounting on shank
or loose stylus.
Check and tighten as appropriate.
Environmental or physical
change caused an error in
calibrated offset.
Review probing software.
Repeat calibration routine.
Calibration out of date and/or
incorrect offsets.
Review probing software.
Calibration and probing speeds
not the same.
Review probing software.
Calibration feature has moved.
Correct the position.
Measurement occurs as stylus
leaves surface.
Review probing software.
Measurement occurs within
the machine’s acceleration and
deceleration zone.
Review probing software and
probe filter settings to increase
back off distance.
Probing speed too fast or too
slow.
Perform simple repeatability trials
at various speeds.
Temperature variation causes
machine and workpiece
movement.
Minimise temperature changes.
Machine tool faulty.
Perform health checks on
machine tool.
Excessive machine vibration.
Change trigger filter setting.
Eliminate vibrations.
Summary of Contents for RMP60
Page 1: ...RMP60 QE radio machine probe Installation guide H 6587 8520 01 A...
Page 6: ...RMP60 installation guide iv Contents This page is intentionally left blank...
Page 12: ...RMP60 installation guide 1 6 Before you begin This page is intentionally left blank...
Page 24: ...RMP60 installation guide 2 12 RMP60 basics This page is intentionally left blank...
Page 64: ...RMP60 installation guide 7 6 Fault finding This page is intentionally left blank...
Page 67: ......