1-2
CNC
machine
control
TYPICAL PROBE SYSTEMS
Optional - PSU3
power supply unit
Stylus
Mounting
bracket
Workpiece
MI 5, MI 8 or MI 8-4
interface unit
MI 12 interface unit
or
MI 12 board
LP2 or LP2H
inspection probe
Typical tool
setting probe
Socket for LP2
Lathe
turret
Cable
LTO2-OMP
O-M-I
(one only)
+ CNC control
OMM
(one or two)
+ MI 12
+ CNC control
Signals are transmitted
between the probe and the
machine control, via the
OMP and OMM + MI 12
or alternatively the OMP
and O-M-I.
Interface units convert
probe signals into an
acceptable form for the
CNC machine control.
Optional - PSU3
power supply unit
OMM
- Optical module machine
OMP
- Optical module probe
O-M-I
- Optical machine interface
The LTO2-OMP mounts in a tool
position on the lathe turret.
A workpiece set-up or inspection
cycle may be introduced at any
stage of the machining process.