SYSTEM PERFORMANCE
OPERATING ENVELOPE
See pages 1-4 and 1-5
Natural reflective surfaces within the machine may
increase the signal transmission range.
Coolant residue accumulating on the OMP, OMM
or O-M-I windows will have a detrimental effect
on transmission performance. Wipe clean as often as
is necessary to maintain unrestricted transmission.
Peformance in ambient temperature range 5°- 50° C
(41°- 122° F) is shown on pages 1-4 and 1-5.
Operation in temperatures of 0° to 5° C or 50° to 60° C
(32° to 41° F or 122° to 140° F) will result in some
reduction in range.
WARNING
If two systems are operating in close proximity to each
other, take care to ensure that signals transmitted from
the OMP on one machine, are not received by the OMM
or O-M-I on the other machine, and vice versa.
OMM and O-M-I POSITION
To assist finding the optimum position of the OMM
during system installation, signal strength outputs
are available on the MI 12 interface. O-M-I signal
strength is displayed on an O-M-I multi-coloured
LED.
PROBE-LTO2
OMM MI 12
O-M-I PSU3
Storage
-10°C to 70° C (14°F to 158° F)
Operating
5°C to 50° C (41°F to 122° F)
TEMPERATURE
ENVIRONMENT