1-19
1
2
3
4
5
6
MAGNETIC LABEL
To assist the machine operator,
a summary of O-M-I LED
activity is provided on a
magnetic label, which may be
attached to the machine tool.
KEEP WINDOW CLEAN
To fully maintain
effective signal
transmission
3. LED (clear x 3)
These
LEDs transmit infra-red control
signals to the probe.
4. LED (red) – LOW BAT.
When the OMP battery voltage falls below
a set level, the low battery output device
changes state, and causes the LOW BAT
LED to commence flashing on and off
4 times per second.
Replace the OMP battery as soon as is
practicable after the LED starts flashing.
5. LED (red, green) – PROBE STATUS.
This bi–colour LED is lit when the O-M-I is powered.
Green
-
Probe is seated.
Red
-
Probe is triggered or an
error has occurred.
The change of colour of this LED will coincide with the
Probe Status output devices changing state.
6. LED (red) – ERROR.
Lit when an error condition exists.
i.e. optical beam obstructed, probe out of optical range,
probe has switched off or battery is exhausted.
When an error condition exists the Probe Status output
will be held in a triggered state and the Probe Status LED
will be RED.
The Error LED illuminating will coincide with the error
output device changing state.