5.2.2 Setting of the LPT Interface
LPT communication uses a parallel interface (printer interface) of the personal computer.
LPT communication can only be used on the PC4701U/M emulator.
To set the LPT communication, click the "LPT" radio button of the MCU tab in the Init dialog. The
setting looks like the figure below.
Specify the mode for data transfers in the Type field.
•
The LPT interface has four modes for data transfers, Nibble, Byte, ECP, and EPP. Their modes
are documented in the IEEE-1284 standard. The mode possible to use depends on the PC with
the debugger.
•
When selecting AUTO, the debugger detect the LPT interface at the start and select a mode
possible to use which give better performance automatically. In some PC, the debugger cannot
detect the most suitable mode. Check the mode which the LPT interface in the PC have and
select it from Nibble, Byte, ECP or EPP, if cannot.
•
Start the BIOS setup program of the PC for checking the mode possible to use. How to start and
use the BIOS setup program depends on each PC, so refer the manuals of the PC.
Display of BIOS Setup
Comm nication Mode
u
SPP, Standard Parallel Port, Output Only
Nibb
le
Bidirectional, Bi-directional
Byte
ECP, Extended Capabilities P rt
o
ECP
EPP, Enhanced Parallel Port
EPP
The address displayed in the parallel port base address field is the I/O address.
Specify the I/O address set in the BIOS setup program, in the I/O Address field. (The following
addresses are possible to be specified)
•
378h
•
278h
46
Summary of Contents for Emulator Debugger M16C PC4701
Page 13: ...Setup of Debugger 1...
Page 14: ...Blank Page 2...
Page 73: ...Tutorial 59...
Page 74: ...Blank Page 60...
Page 95: ...Reference 81...
Page 96: ...Blank Page 82...
Page 128: ...Example Writing byte length data 32h to even address 400h 114...
Page 130: ...16 bits bus width 116...
Page 132: ...2nd point 118...
Page 133: ...7 Windows Dialogs 16 bits bus width 119...
Page 134: ...Example Writing data 10h 3Fh to even address 400h 120...
Page 138: ...Example Writing byte length data 32h to even address 400h 124...
Page 140: ...16 bits bus width 126...
Page 141: ...7 Windows Dialogs Example Writing word length data 1234h to even address 400h 127...
Page 142: ...Example Writing data 10h 3Fh to even address 400h 128...
Page 146: ...Example Writing byte length data 32h to even address 400h 132...
Page 147: ...7 Windows Dialogs Example Writing data 10h 3Fh to even address 400h 133...
Page 153: ...7 Windows Dialogs 7 7 8 2 Interrupt Termination Set as below 139...
Page 172: ...For condition 7 choose the Mode shown below and set the Start event 158...
Page 294: ...MEMO 280...