Heating capacity SKT 1060
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
5,00
5,50
6,00
6,50
7,00
7,50
8,00
8,50
9,00
9,50
10,00
10,50
11,00
11,50
12,00
12,50
13,00
13,50
-15
-7
-5
0
7
12
2
1
3
A
[°C]
Fig. 6: Performance curves, heating SKT 1060 (data for room temperature 20 °C)
A: Outside temperature
1: COP
2: Heating capacity in kW
3: Power consumption in kW
Outside temperature in °C
-15
-7
-5
0
7
12
Heating capacity in kW
6.08
6.42
6.92
8.10
11.14
12.68
Power consumption in kW
2.53
2.57
2.63
2.74
3.00
3.05
COP
2.40
2.50
2.64
2.96
3.71
4.16
Cooling capacity SKT 1060
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
5,00
5,50
6,00
6,50
7,00
7,50
8,00
8,50
9,00
9,50
10,00
10,50
11,00
11,50
12,00
21
25
30
35
40
2
1
3
A
[°C]
Fig. 7: Performance curves, cooling SKT 1060 (data for room temperature FK 27 °C/TK 19 °C)
A: Outside temperature
1: EER
2: Cooling capacity in kW
3: Power consumption in kW
Outside temperature in °C
21
25
30
35
40
Cooling capacity in kW
10.19
10.86
10.96
10.55
9.05
Power consumption in kW
3.03
3.27
3.56
3.89
3.95
EER
3.36
3.32
3.08
2.71
2.29
13