(3) Cooling capacity - Heating capacity OU / IU
Display
Cooling
capacity
(kW)
Heating
capacity
(kW)
1
2.0-2.5
2.0-2.5
2
2.0-2.5
2.0-2.5
3
3.0-3.8
3.0-3.8
4
4.5-5.0
4.5-5.0
5
5.0
5.5-6.1
6
5.5-6.1
6.1-7.0
7
6.1-7.0
6.1-7.0
8
7.0-7.5
7.0-7.5
9
7.5-8.0
7.5-8.0
10
>8.0
>8.0
(6) Hot gas temperature probe
Display
Temperature (°C)
10
35-40
11
40-45
12
45-50
13
50-55
14
55-60
15
60-65
16
65-70
(5) Air inlet temperature probe
Display
Temperature (°C)
15
-7.5
20
-5.0
25
-2.5
30
0
35
2.5
40
5.0
45
7.5
50
10.0
55
12.5
60
15.0
65
17.5
Display
Temperature (°C)
70
20.0
75
22.5
80
25.0
85
27.5
90
30.0
95
32.5
99
34.5
(7) Outdoor unit current consumption
Display
Current consump. (A)
44
6.0
46
6.2
54
7.4
55
7.6
58
7.8
62
8.0
66
8.6
67
8.8
68
9.0
70
9.2
72
9.5
76
10.0
78
10.2
80
10.4
82
10.6
84
11.0
88
11.6
92
12.0
94
12.2
35