Heating capacity RVT 355 DC
Inside
Outside temperature (TK, °C)
-25
-20
-15
-10
Heating capacity (A = Total, B = Sensitive, C = Power consumption)
TK
A
C
A
C
A
C
A
C
°C
kW
kW
kW
kW
kW
kW
kW
kW
15
2.76
1.83
3.02
1.92
3.72
1.95
3.90
1.89
18
2.72
1.86
2.98
1.95
3.67
1.98
3.84
1.92
20
2.68
1.89
2.93
1.98
3.61
2.01
3.78
1.95
22
2.62
1.90
2.87
2.00
3.54
2.03
3.71
1.97
24
2.60
1.92
2.84
2.02
3.50
2.05
3.67
1.99
25
2.57
1.93
2.82
2.03
3.47
2.06
3.63
2.00
27
2.54
1.95
2.79
2.05
3.43
2.08
3.59
2.02
Inside
Outside temperature (TK, °C)
-7
2
7
10
Heating capacity (A = Total, B = Sensitive, C = Power consumption)
TK
A
C
A
C
A
C
A
C
°C
kW
kW
kW
kW
kW
kW
kW
kW
15
4.42
1.88
4.60
1.88
4.38
0.91
4.16
0.82
18
4.36
1.91
4.53
1.90
4.31
0.93
4.10
0.84
20
4.29
1.94
4.46
1.93
4.25
0.94
4.04
0.85
22
4.21
1.96
4.37
1.95
4.17
0.95
3.96
0.86
24
4.16
1.98
4.33
1.97
4.12
0.96
3.92
0.87
25
4.12
1.99
4.28
1.98
4.08
0.97
3.88
0.87
27
4.08
2.01
4.24
2.00
4.04
0.98
3.84
0.88
15