background image

Instruction Manual  
Radio control devices T3, T5 and T7 @ 

2G4

 

version 1.3 January 14

 

REM

device

®

 - ITALY

 

 page 11 of 28 

TX OFF

TX ON

Command

TX ON

TX OFF

 Power ON

Power OFF

REM

device

RADIO CONTROL EQUIPMENT

Frequency 

Serial Number

Power Supply

!

R

U

B

Y

-B

O

X

 R

E

C

E

IV

E

R

TECHNICAL DATA

Protection degree: IP67
Material: ABS V0

REMsys CODE

Link System

PATENTED - BREVETTATO

90 mm

2

6

0

 m

m

The 

RubyBox-Terminal

  unit,  outdoor  box  must  be  placed  in  a 

location easily accessible to maintenance personnel and repair. 
Connecting  the 

Rx2G4A  Antenna

  to  receiver  RubyBox-Terminal  is 

made via  the  supplied  cable,  or  alternatively  a  cable 6x0,25  twisted 
pair. Observe the colour of the wires as shown on the label near the 
plug. 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Rx2G4A 

Rx2G4 Antenna 

 

SERIAL 

NUMBER 

Figure 4 

RBT

 

RubyBox-Terminal 

Instruction Manual  
Radio control devices T3, T5 and T7 @ 

2G4

 

version 1.3 January 14

 

page 12 of 28 

REM

device

®

- ITALY

 

The  Rx2G4A  receiver  must  not  be  positioned  inside  screened  metal 
structures  (boxes,  cupboards,  trellises,  tubes,  grids,  etc.),  so  as  not 
to  jeopardise  the  reception  of  the  radio  signal;  For  better  efficiency 
must be placed in the area above the work area. 
The  measurements  for  drilling  the  holes  for  Ruby-terminal  are 
indicated in Figure 4. 
Never make a hole in the box. Avoid precarious fixing systems. 

 

For  correct  and  safe  wiring  of  the  Terminal,  use  a  multicore  cable 
and  plug  of  the  same  type  as  those  used  for  the  wired  pushbutton 
panel supplied with the machine. 
Use  caps  to  terminate  the  leads  to  be  tightened  to  the  receiver 
terminals and check the fastening accurately. 

 

The  simultaneous  control  of  an  operating  machine  with  the  radio 
control device and the wired pushbutton panel is NOT allowed. 
Pay  particular  attention  to  the  connection  of  the  STOP/EMERGENCY 
circuit,  following  and  respecting  the  machine’s  original  wiring 
diagram. 

 

Supplying power to the Receiver 

Check that there is a suitable isolating device on the machine. Use a 
voltmeter to check that there is a suitable voltage on the machine’s 
electric  panel  to  supply  the  receiver.  These  feeding  voltage  values 
are  given  in  the  paragraph  TECHNICAL  CHARACTERISTICS  and 
printed next to the connecting terminals, inside the receiver.  

The phase and neutral or positive and negative polarities are 
indifferent. 

The  characteristics  of  the  receiver  relay  contacts  are  given  in  the 
paragraph TECHNICAL CHARACTERISTICS.. 
The  presence  of  voltage  on  the  receiver  is  indicated  by  the  Green 
Led ON with a fixed light. 

Summary of Contents for T3 @ 2G4

Page 1: ...or correct and safe use of the radio control device 4 Installation of the radio control device 8 Arrangement and description of controls 10 Inspection of the radio control device 15 Keeping the radio control device in good working order 16 Changing the battery 17 Changing the transmitter 18 Programming the radio control device 19 Conformity 20 Diagnostics 23 Operating principle 24 Identification o...

Page 2: ...g Area Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 4 of 28 REMdevice ITALY INSTRUCTIONS FOR CORRECT AND SAFE USE OF THE RADIO CONTROL DEVICE The use of the radio control device is reserved to expert operators who have read the instructions on the conditions of use of the radio controlled machine and who respect the safety regulations imposed by law in the ...

Page 3: ...the radio control device Press the control buttons for the desired function taking care as they may be of the type with a sequential double click by increasing the pressure on the button a second contact is made that is normally assigned to increasing the speed of a machine movement If any kind of difficulty occurs in controlling the operating machine for mechanical or electrical reasons or at any...

Page 4: ...about 2000 hours continuous duty 1 2 3 4 5 6 7 S Figure 2 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 8 of 28 REMdevice ITALY INSTALLATION OF THE RADIO CONTROL DEVICE REMdevice is at the disposal of installation technicians to supply useful information that will ensure the correct installation and commissioning of the radio control device Training of perso...

Page 5: ...ment requires it it is necessary to provide protective measures to prevent reduce and report situations of potential danger Must be considered that The remote control T7 is not suitable for installation in environments requiring explosion proof equipment machines for handling lifting and transportation of people or machines that could lead to dangerous situations in the event of shutdown due to lo...

Page 6: ...rea The measurements for drilling the holes for Ruby terminal are indicated in Figure 4 Never make a hole in the box Avoid precarious fixing systems For correct and safe wiring of the Terminal use a multicore cable and plug of the same type as those used for the wired pushbutton panel supplied with the machine Use caps to terminate the leads to be tightened to the receiver terminals and check the ...

Page 7: ...l devices T3 T5 and T7 2G4 version 1 3 January 14 page 14 of 28 REMdevice ITALY Arrangement of controls in the receiver RBT T7 0V 24 48V 115V 230V Receiver power supply STOP Stop Emergency Contact N C with transmitter active START Start Contact N O CLAX Horn Contact N O it closes with the START command LAMP Contact for flashing light N C with transmitter active ABIL Enabling Contact N O it closes ...

Page 8: ...e movements give the various commands in the different zones of the work area to ensure that it is fully covered by the radio signal At the end of inspection clearly fill in the wiring diagram of the receiver and sign the declaration of correct installation The serial number of the radio control device to be given on the documentation is indicated on the Receiver fig 4 and is not on the Transmitte...

Page 9: ...and T7 2G4 version 1 3 January 14 page 18 of 28 REMdevice ITALY CHANGING THE TRANSMITTER In the event of malfunction breakage or loss of the transmitter it is possible to replace it with a new one The programming of the code involves only the transmitter while the receiver is combined and tuned automatically thanks to the exclusive new patented REMSYS CODE System For this reason the serial number ...

Page 10: ...1 2 3 4 5 6 7 S RED LED TENS GREEN LED UNITS Figure 10 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 20 of 28 REMdevice ITALY Tables of frequencies Band 2 4 GHz CH6 2 41075 CH7 2 41275 CH8 2 41475 CH9 2 41675 CH10 2 41875 CH11 2 42075 CH12 2 42275 CH13 2 42475 CH14 2 42675 CH15 2 42875 CH16 2 43075 CH17 2 43275 CH18 2 43475 CH19 2 43675 CH20 2 43875 CH21 2 4...

Page 11: ... Button 7 EXCLUDED Button 7 ACTIVE Button 7 ACTIVE Relay A Relay A B with CR1 or CR3 Button 4 AUXILIARY BUTTON Button 7 ACTIVE Relay CR13 Pulse Button 7 ACTIVE Relay CR13 Step by step Button 7 ACTIVE Relay A Relay B Relay A B Button 5 1 2 3 4 5 6 7 S RED LED GREEN LED Figure 11 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 22 of 28 REMdevice ITALY Change of ...

Page 12: ...the led PWR lit Has frequency been changed Check STOP fuse Does the machine start Are all manoeuvres working Machine working Have you checked STOP fuse NO YES NO YES YES NO YES NO YES YES NO NO NO YES YES NO Is the red led blinking START UP at low power approach the machine NO YES Figure 13 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 24 of 28 REMdevice ITA...

Page 13: ...10 8 less than 1 in 100 000 000 24 bits are used for the control code 8 bits are used for setup The 48 address bits are used to couple the transmitter to the receiver with a code which is set by the manufacturer and assigned univocally to each radio control device produced using the new and exclusive REMSYS CODE system Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 1...

Page 14: ...Y GUARANTEE CONDITIONS REMdevice guarantees the radio control device for 12 months The starting date of the guarantee period is that of the transport document The guarantee is valid only for appliances that present manufacturing defects The radio control device MUST NOT have undergone attempted repairs tampering or replacement of parts by personnel not authorised by REMdevice The guarantee is void...