RP3000 Adjustment Description
-22-
Wideband
Turn to CH12.
See CTCSS deviation
adjustment.
Adjust it to 3KHz
±
0.1KHz.
Press [A] to save.
9.TONE
deviation
Narrow-band
See CTCSS deviation
adjustment.
Radio
Communication
Test Set
LPF: 3KHz
ANT
[B] (up)
[C] (down) Adjust it to 1.45KHz
±
0.05KHz
Press [A] to save.
10. Low battery alert level
Turn to CH15. Adjust
voltage to 6.1V.
Digital Voltmeter
Press [A] to save.
11.VOX Sensitivity
Turn to CH16.
Radio
Communication
Test Set
LPF: 15KHz
AF: 1KHz 3mV
ANT
MIC Jack