background image

 

 5 

  Safety Notes 

  General Safety Notes 

  All equipment undergoes final inspection and testing before leaving our factory. However, 

if equipment is damaged during shipping or through any other circumstances, it must not 

be used in service. Please check the device regularly for damages. Damaged parts 

should be replaced immediately. 

  All power/air/water/gas sources should be rated for the demands of the device as listed in 

the technical data sheets. Maximum ratings must not be exceeded. All VDE (Verein 

Deutscher Elektro-Ingenieure) standards should be followed. Equipment should be 

grounded according to standards. 

  Adherence to valid regulations regarding necessary checks (e.g. according to Accident 

Prevention & Insurance or electrical equipment) is exclusively taken over by the 

buyer/user of this product. 

  This device has been designated to be used only for its intended purpose. All other 

applications must be prohibited for safety reasons as otherwise the manufacturer’s 

warranty expires. 

  The device should be set-up in a clean, well-ventilated room, if necessary under a hood. 

  Supporting surfaces should be straight, flat and adequately stable. 

 

Don’t place anything on top of the machine. 

  To avoid injury, appropriate protection should be worn (e.g. gloves, safety glasses, safety 

shoes, hearing protection etc.) 

  If the machine is defective or working improperly it must be taken out of service. In case 

of further use of the machine the owner will be held responsible for any consequential 

damage. 

  To prevent accidents from water, fire or explosion, all power/air/water/gas sources should 

be turned off after working hours and during breaks, and secured against unauthorized 

access. 

  When carrying out maintenance works or repairs or when opening the device always turn 

off the main power switch and unplug the whole unit. 

  Repairs should be carried out only by the manufacturer or by qualified and certified 

personnel appointed according to chapter 7 

– warranty. 

  In case of leaking water out of housing or tank shut down device and call service. 

 

 

Summary of Contents for DUSTY COMFORT

Page 1: ...Operating Instructions LABORATORY EQUIPMENT REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel com DUSTY COMFORT...

Page 2: ...vice life Prior to installation of the device operating instructions and especially the safety instructions must be read and followed by all personnel who use this device After having unpacked the dev...

Page 3: ...ILTER INSTALLATION 7 CONNECTION OF POWER TOOLS 7 NOTES FOR THE USER 8 OPERATION 8 REPLACING FILTER BAG OR FINE DUST FILTER ELEMENT 8 PICKING UP DRY SUBSTANCES 9 PICKING UP LIQUIDS 9 EMPTYING THE DIRT...

Page 4: ...Single workplace suction unit DUSTY COMFORT 2 5 m suction hose 7 5 m cable Fine dust filter element 1 piece preassembled Filter bag 1 piece Cyclone insert Special Accessories Order No 27905000 Filter...

Page 5: ...d for safety reasons as otherwise the manufacturer s warranty expires The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces should be straight flat...

Page 6: ...ket ensure that the voltage shown on the rating plate corresponds to the voltage of the local mains power supply Prior to picking up liquids the filter bag must be removed and the float lever needs to...

Page 7: ...tting in the dirt tank see detail 3 3 Attach the upper section of the suction 6 Close the retaining clamps 8 see detail 9 Ensure that the retaining clamps fit properly Connection of power tools 1 Ensu...

Page 8: ...on the power tool the suction is started e As soon as you switch off power tool the suction switches off automatically after some seconds f When work is finished switch off the suction with the power...

Page 9: ...t clockwise see detail 6 to secure it 3 Remove the filter bag see chapter 4 2 Emptying the dirt tank 1 Open the retaining clamps see chapter 3 3 and remove the upper section of the suction unit 2 Tip...

Page 10: ...dirty clean it Maintenance Regularly check the device s state Pay attention to visible damage to housing or power cord Regularly replace the filter bag see chapter 4 2 Replacing filter bag or fine dus...

Page 11: ...ssed to the distributor the product was purchased from or directly to our service department Contact REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 32 Service Dep...

Page 12: ...ages due to faulty installation or insufficient maintenance of the product e g decalcification Damages due to natural disaster e g lightning water fire act of nature beyond control war inadequate line...

Page 13: ...dvised to backup essential programs and data before sending for service 12 This warranty shall be interpreted in accordance with German law to the exclusion of UN sales law Place of jurisdiction is ou...

Page 14: ...posal Pls contact your local dealer for additional information Technical Data Line voltage 230 V 50 60 Hz Current consumption 1 300 W Plug max 1 500 W auto Height width depth 600 360 420 mm Weight 7 8...

Page 15: ...3 Inlet fitting 4 Suction hose 5 Handle with receptacle for electrical lead 6 Upper section of the vacuum cleaner light grey 7 Suction power control switch 8 Retaining clamp 9 Dirt tank dark grey 10 A...

Page 16: ...16 Detail 1 Detail 2 Detail 4 Detail 3 Detail 5 Detail 6 Detail 7 Detail 8 Detail 9...

Page 17: ...EC Conformity Declaration...

Page 18: ......

Page 19: ......

Page 20: ...pliance with quality management ISO 9001 2015 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com in...

Reviews: