TESTING CONCEPTS AND RECOMMENDED TEST SEQUENCE
24
Test Types
When executing the tests under the
Sequencing
Mode
, the tests that the TALAN will perform
includes those selected using the
TEST TYPE
selection. The TALAN will automatically utilize
default settings for the various test functions.
The
TEST TYPE
can be configured by the user as necessary. There are “quick set” buttons for
Block
,
Phone
,
ALL
, and
NONE
. These buttons will set the appropriate set of tests for
VDC
(Volts
DC),
VAC
(Volts AC),
RES
(Resistance),
CAP
(Capacitance),
IDC
(current DC), and
IAC
(current
AC). Below is an example of the Stage 1 (On-Hook) DMM tests where the
TEST TYPE
was set to
All Pairs and All Wires for all test types.
Subsequently, when
START
is pressed, the TALAN will test all pairs and wires for all tests.
The default factory settings for
BLOCK
and
PHONE
are as follows:
TEST TYPE
Block
Phone
VDC (Voltage DC)
Balanced Pairs
Balanced Pairs
VAC (Voltage AC)
None
None
RES (Resistance)
Balanced Pairs
Balanced Pairs
CAP (Capacitance)
None
None
IDC (DC Current)
All Wires
None
IAC (AC Current)
None
None