MANUAL TEST FUNCTIONS
39
The same testing controls for Manual DMM is permitted for the
Shield
and
EarthGround
tests.
E.g. Selection of
Tests
,
Range
,
Dwell
, etc.
The right dashboard
Connection
s display can be used to control the selections when the
Wire
To Test
is set to
Selected Wire
. The following figure shows a test of resistance with 265K
resistance between
Wire 4
of a CAT6 cable plugged into the Phone jack and the
Shield
of the
CAT6 cable:
The DMM Measurements taken against
Shield
and
EarthGround
connections can be saved in a
TALAN Job file which can then be viewed on a PC running the TALAN Data Viewer V3.0 in the
Manual Test data section.