Maintenance and repair
65
13.2 Maintenance table
The maintenance intervals are recommended by REHM for standard
requirements (for example, single shift operation, use in a clean and dry
environment). The precise maintenance intervals are specified by your safety
officer.
Activity
Sectio
n
Interval
Cleaning the inside of the unit
14.3
min 2 x per year
Checking cooling water and the cooler
14.4
Daily
Functional test of the safety equipment
by operating personnel
Daily
Visual system check, particularly the
connection cables and torch hoses
Daily
Have the connecting lines and torch
hoses checked by qualified personnel;
log the checks in the logbook provided.
Perform
checks
more
regularly
depending on the country-specific
laws.
Every six months
Have the complete welding system
checked by qualified personnel; log the
checks in the logbook provided.
Perform
checks
more
regularly
depending on the country-specific
laws.
Annually
13.3 Cleaning the inside of the unit
If the
REHM
welding unit is used in a dusty environment the inside of the unit
must be cleaned at regular intervals by blowing out or vacuuming.
The frequency of this cleaning depends on the respective conditions of use,
however, it should be carried out at least twice a year. Only use clean, dry air to
blow out the unit or use a vacuum cleaner.
Summary of Contents for FOCUS.ARC P 250
Page 1: ...GB OPERATING INSTRUCTIONS MIG MAG impulse welding systems FOCUS ARC P 250 450...
Page 16: ...Function description 16 Figure 5 FOCUS ARC P wire feed case...
Page 37: ...Function description 37 Figure 20 Submenu MSG parameters...
Page 67: ...Circuit diagrams 67 14 Circuit diagrams Figure 28 FOCUS ARC P current source...
Page 68: ...Circuit diagrams 68 Figure29 FOCUS ARC P wire feed case...
Page 69: ...Circuit diagrams 69 Figure30 FOCUS ARC P water cooling...
Page 73: ...Components 73...
Page 74: ...Components 74...
Page 75: ...Components 75...
Page 76: ...Components 76...
Page 81: ......