Commissioning
57
Important!
When using a gas-cooled torch on a water-cooled system, the water
connections must be connected via a hose bridge or the water cooling
must be set to "Off" in the Setup submenu so that the water pump is not
damaged.
10.9 Inserting the wire
After inserting the wire on the coil mandrel, thread the wire manually through the
guides to the feed rolls. Ensure that you use the appropriate drive rollers
according to the wire diameter and wire type (solid). When the wire has been
inserted into the guide of the torch hose set past the second drive roller, fold the
pressure rollers onto the wire and fix them. Now thread the wire by pressing the
pushbutton Threading (Fig. 4). Ensure that the torch runs as straight as possible
without kinks in order to avoid complicating threading and to prevent the wire
from buckling or damaging the wire liner.