Function description
28
Hotstart
current
t (s)
Current
[A]
Hotstart
Time
Drop time
Welding
current
Slope-down
current
Hotstart
Slope
time
5.2.4 4 cycle operating mode with slope-down (Slope)
4 cycle operating mode procedure with slope-down (Slope):
1. cycle Operate the torch trigger
The inert gas solenoid valve opens
After the set gas pre-flow time has expired the power unit is switched on.
Welding voltage on
Wire feed runs at the initial wire feed speed
Arc is ignited after the welding wire contacts the workpiece
The feed switches to the set wire feed speed of the welding process
The welding current flows with the set Hotstart value
2. cycle Release the torch trigger
The welding current is changed from the Hotstart value to the value set
for welding
3. cycle Operate the torch trigger
For the duration of the slope-down time, the welding current is reduced to
the value set for the slope-down current
4. cycle Release the torch trigger
Wire feed stops
Freeband and freeband control are executed
The inert gas is switched off after the gas post-flow time has expired
Figure 15:
4 cycle operating mode procedure slope-down (Slope) with
Hotstart
Summary of Contents for FOCUS.ARC P 250
Page 1: ...GB OPERATING INSTRUCTIONS MIG MAG impulse welding systems FOCUS ARC P 250 450...
Page 16: ...Function description 16 Figure 5 FOCUS ARC P wire feed case...
Page 37: ...Function description 37 Figure 20 Submenu MSG parameters...
Page 67: ...Circuit diagrams 67 14 Circuit diagrams Figure 28 FOCUS ARC P current source...
Page 68: ...Circuit diagrams 68 Figure29 FOCUS ARC P wire feed case...
Page 69: ...Circuit diagrams 69 Figure30 FOCUS ARC P water cooling...
Page 73: ...Components 73...
Page 74: ...Components 74...
Page 75: ...Components 75...
Page 76: ...Components 76...
Page 81: ......