30 |
Regency Ultimate™ U1500E Gas Fireplace
installation
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Horizontal Venting with Two (2) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
With these options,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
1' Min.
3' Max.
B)
2' Min.
4' Max.
C)
3' Min.
5' Max.
D)
4' Min.
6' Max.
E)
5' Min.
7' Max.
F)
6' Min.
8' Max.
Restrictor Set 0 - 5" Factory
Setting
Option
V
H
V + V1 H + H1
With these options,
max. total pipe
length is 30 feet with
min. of 12 feet total
vertical and max. 9
feet total horizontal.
Please note min. 1
foot between 90
o
elbows is required.
A)
0' Min.
1' Max.
1' Min.
2' Max.
B)
1' Min.
2' Max. 3' Min. 3' Max.
C)
2' Min.
2' Max.
5' Min.
4' Max.
D)
3' Min. 2' Max.
7' Min.
5' Max.
E)
4' Min.
3 Max.
9' Min.
6' Max.
F)
5' Min.
4' Max.
10' Min.
7' Max.
G)
6' Min. 5' Max.
11' Min.
8' Max.
H)
7' Min.
6' Max.
12' Min.
9' Max.
Restrictor Set 0 - 5" Factory Setting