Regency P33 Sunrise™ Gas Fireplace
37
INSTALLATION
OPTIONAL REFLECTIVE PANEL INSTALLATION
1)
If already installed, remove the burner assembly and fi rebox base
(See installation manual for instructions).
2)
Remove 4 screws prior to top panel installation.
Diagram 2
Diagram 3
Back Panel
Diagram 1
Diagram 5
Diagram 6
3)
Place the top panel in fi rst, secure with 4 screws.
(See Diagram 1 for screw locations)
4)
With the top panel in place - install back panel. The back panel fi ts
under the top panel, push the top panel up to fi t back panel into
position. (Diagrams 3)
5)
The side panels are installed last, slide in as shown in Diagram 6.
Note:
The bend in the metal on the side panels should face outward
(toward inside of fi rebox - see
Diagram 5
). If the side panels have
been installed incorrectly the fi rebox base will not fi t.
6)
Reinstall the fi rebox base and burner assembly.
Before installation, panels must be handled and cleaned as per instructions noted below:
Stainless Steel Panels
Black Enamel Panels
•
Stainless panels must be inspected for scratches and dimples prior
to installation. All claims to be recorded at this time. Claims for dam-
age after installation will not receive consideration.
•
Black Enamel panels must be inspected for scratches and dimples
prior to installation. All claims to be recorded at this time. Claims for
damage after installation will not receive consideration.
•
To protect the fi nish during installation and handling
- cotton
gloves
MUST
be worn at all times while handling the panels (even when
removing protective coating).
•
Use a hair dryer to remove the protective coating from the panels.
•
Stainless panels will discolor a little during normal operation.
This is normal and should not be considered a defect.
•
Black Enamel panels will discolor a little during normal operation.
This is normal and should not be considered a defect.
*
All hand and fi nger marks
MUST
be cleaned off with a soft cloth and
a stainless steel cleaner. Most stainless steel cleaners leave a fi lm/
residue on the surface of the panels. Use an ammonia based cleaner
(ie. glass cleaner) to remove this fi lm before applying heat to the unit.
Failure to do this will result in burn stains on panels which you
will be unable to remove.
Not protected by product warranty.
*
All hand and fi nger marks
MUST
be cleaned off with a soft cloth. Use
an ammonia based cleaner (ie. glass cleaner) to remove any fi ngerprints
before applying heat to the unit.
Failure to do this will result in burn stain on panels which you
will be unable to remove.
Not protected by product warranty.
Completed Panel Installation