Regency P33 Sunrise™ Gas Fireplace
25
INSTALLATION
Horizontal Venting with Three (3) 90
o
Elbows
Vertical Venting with Two (2) 90
o
Elbows
Vertical Venting with Two (2) 90
o
Elbows
For additional vertical venting with
2 x 90
o
elbows, refer to "Rigid Pipe
Venting Arrangements" Section.
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V + V1
H + H1
With these options,
maximum total pipe
length is 30 feet with
minimum of 12 feet
total vertical and
maximum 9 feet total
horizontal.
P l e a s e n o t e
m i n i m u m 1 f o o t
between 90
o
elbows
is required.
A)
2' Min.
1' Max.
3' Min.
4' Max.
B)
3' Min.
2' Max.
4' Min.
5' Max.
C)
4' Min.
3' Max.
6' Min.
6' Max.
D)
5' Min.
4' Max.
8' Min.
7' Max.
E)
6' Min.
5' Max.
10' Min.
8' Max.
F)
7' Min.
6' Max.
12' Min.
9' Max.
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V + V1
With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum 8
feet total horizontal.
Please note minimum
1 foot between 90
o
elbows is required.
A)
1' Min. 4' Max.
2' Min.
B)
2' Min. 5' Max.
3' Min.
C)
3' Min. 6' Max.
4' Min.
D)
4' Min. 7' Max.
5' Min.
E)
5' Min. 8' Max.
6' Min.
One 90
o
elbow = Two 45
o
elbows.
Option
H + H1
V
With these options, maximum
total pipe length is 30 feet
with minimum of 6 feet total
vertical and maximum 6 feet
total horizontal.
Please note minimum 1
foot between 90
o
elbows is
required.
A)
2' Max.
2' Min.
B)
3' Max.
3' Min.
C)
4' Max.
4' Min.
D)
5' Max.
5' Min.
E)
6' Max.
6' Min.