44
Regency P33 Sunrise™ Gas Fireplace
MAINTENANCE
MAINTENANCE
INSTRUCTIONS
1)
Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year.
2)
Clean appliance and door with a damp
cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas
fi
replace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.
3)
The faceplate is
fi
nished in a heat resistant
paint and should only be re
fi
nished with heat
resistant paint. Regency
®
uses StoveBright
Paint - Metallic Black #6309.
4)
Make a periodic check of burner for proper
position and condition. Visually check the
fl
ame of the burner periodically, making sure
the
fl
ames are steady; not lifting or
fl
oating.
If there is a problem, call a quali
fi
ed service
person.
5)
The appliance and venting system must be
inspected before use, and at least annually,
by a quali
fi
ed
fi
eld service person, to ensure
that the
fl
ow of combustion and ventilation
air is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6)
Do not use this appliance if any part has been
under water. Immediately call a quali
fi
ed
service technician to inspect the appliance
and to replace any part of the control system
and any gas control which has been under
water.
7)
In the event this appliance has been
serviced check that the vent-air system
has been properly resealed & reinstalled
in accordance with the manufacturer's
instructions.
8)
Verify operation after servicing.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1)
Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
immediately.
2)
Remove the Cap, and shine a
fl
ashlight
down the Vent. Remove any bird nests, or
other foreign material.
3)
Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and
fi
ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
cold weather.
4)
Inspect joints, to verify that no pipe
sections or
fi
ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
THERMOPILE /
THERMOCOUPLE
1)
Shut the power off.
2)
Remove the Faceplate by lifting up off
fl
ush
door.
3)
Remove the control assemby plate.
4)
Remove the standard
fl
ush door.
5)
Remove the Cobalt Glass Crystals or
Ceramic Stones.
6)
Remove the 2 screws holding the pilot
cover.
7)
Loosen the thermocouple or thermopile with
a 7/16" wrench.
8)
Disconnect thermocouple by loosening nut
from the valve with 9mm wrench. Disconnect
thermopile by loosening 2 screws marked
TP on the valve.
9)
Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
10)
Reinstall the new ones in reverse order.
CAUTION: Wear gloves when
removing damaged or broken
glass.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualifi ed service person.
GLASS DOOR
Your Regency
®
fi
replace is supplied with high
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this
fi
replace without the
glass front or with a cracked or broken glass
front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panel(s) should be
done by a licensed or quali
fi
ed service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
®
dealer only.
Replacement glass is shipped already installed
into the door frame.