24
Regency P33 Sunrise™ Gas Fireplace
INSTALLATION
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
With these options, maximum
total pipe length is 30 feet
with minimum of 6 feet total
vertical and maximum 8 feet
total horizontal.
Please note minimum 1
foot between 90
o
elbows is
required.
A)
1' Min.
3' Max.
B)
2' Min.
4' Max.
C)
3' Min.
5' Max.
D)
4' Min.
6' Max.
E)
5' Min.
7' Max.
F)
6' Min.
8' Max.
One 90
o
elbow = Two 45
o
elbows.
Option
H
V
H + H1 + H2
With these options,
maximum total pipe
length is 30 feet with
minimum of 11 feet
total vertical and
maximum 9 feet total
horizontal.
P l e a s e n o t e
minimum 1 foot
between 90
o
elbows
is required.
A)
1' Max.
1' Min.
3' Max.
B)
2' Max.
3' Min.
5' Max.
C)
3' Max.
5' Min.
6' Max.
D)
4' Max.
7' Min.
7' Max.
E)
5' Max.
9' Min.
8' Max.
F)
6' Max.
11' Min.
9' Max.
Horizontal Venting with Two (2) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
H
V
H + H1
With these options,
maximum total pipe
length is 30 feet with
minimum of 8 feet total
vertical and maximum 8
feet total horizontal.
Please note minimum
1 foot between 90
o
elbows is required.
A)
1' Max.
1' Min.
3' Max.
B)
2' Max.
2' Min.
5' Max.
C)
3' Max.
4' Min.
6' Max.
D)
4' Max.
6' Min.
7' Max.
E)
5' Max.
8' Min.
8' Max.