Regency P33 Sunrise™ Gas Fireplace
31
INSTALLATION
WARNING!
Do not overtighten the screw.
Recommended to grip
the wrench by the short side.
9)
Turn control knob to the “OFF” position.
10)
Remove the black protection cap by
hand from the high-low knob (Fig.1).
11)
Insert a 5/32” or 4mm Allen wrench into
the hexagonal key-way of the screw
(Fig. 2), rotate it counter-clockwise until
it is free and extract it.
12)
Check that the screw is clean and if
necessary remove dirt.
13)
Flip the screw (Fig. 3).
14)
Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until
snug, do not overtighten.
15)
Verify that if the conversion is from
NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).
16)
Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and
main burner injectors
are appropriate for the gas type.
Fig. 1
Fig.2
Fig.3
Fig.4
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
17)
Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
18)
Replace yellow "NG" label with red
"LPG" label.
19)
Check for gas leaks.
20)
Check inlet and outlet pressures.
21)
Check operation of fl ame control.
22)
Check for proper fl ame appearance.
23)
Reverse step 2.