26
|
P36E-11 Zero Clearance Direct Vent Gas Fireplace
installation
Side
Nailing Strips
"C" Screw Position:
For a facing material depth of 1-1/4" (32mm), the
top facing support must be reversed.
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The Top Facing Support, the Side Nailing Strips and
the 2 Top Standoffs must be correctly positioned
and attached to the top before unit is slipped into
position.
Top Standoff Assembly
The top standoffs are shipped in a flat position and
must be folded into shape and attached.
1) Remove the standoffs from the fireplace top.
2) Take each standoff and bend into the correct
shape. Bend up at the bend lines until the screw
holes in the standoff and the pre-punched screw
holes on the fireplace top line up.
3) Attach the standoff securely to the top with 2
screws per standoff (on opposite corners).
VENTING
INTRODUCTION
The P36E-11 uses the "balanced flue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer liner
draws outside combustion air into the combustion
chamber thereby eliminating the need to use heated
room air for combustion and losing warm room air
up the chimney.
Note:
These flue pipes must not be connected
to any other appliance.
The gas appliance and vent system must be vented
directly to the outside of the building, and never
be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
Common vent systems are prohibited.
Nailing Strips
Determine the total thickness of facing material
(e.g. non combustible plus ceramic tiles) to allow
the finished surface to be flush with the front of
the unit. Total facing thickness can vary from
1/2" (13mm) to 1-1/4" (32mm) thick.
The Top Facing Support can be mounted in 3
different positions depending on the thickness
of the facing material.
Side
Nailing Strips
2)
Fold out the two nailing strips on each side.
If finishing flush with the Vignette Finishing Trim
-bend nailing strips around side trim pieces as
shown below.
1)
Mount Top Facing Support using the 3 supplied
screws into the three pre-punched screw holes
on the top front of the unit. Use hole positions
A, B, or C depending on your facing depth.
Screw
Position
Facing Material
Depth
A
1/2" / 13mm
B
7/8" / 22mm
C
*
1-1/4" / 32mm
*
For "C" screw position the top facing
support is reversed.
NOTE:
If finishing flush with the Vignette Finishing Trim -
remove top nailing strip (facing support) if already
installed and use the nailing strip supplied with
the Trim.
Nailing strip
supplied
with trim
Remove
Nailing strip
from unit if
installed
Side
nailing
strips bent.