P36E-11 Zero Clearance Direct Vent Gas Fireplace
|
5
safety decal
This is a copy of the label that accompanies each P36E Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
The safety label is located on the front inside base of the unit.
NOTE:
Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
For the State of Massachusetts, installation and
repair must be done by a plumber or gasfitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas
appliance is installed.
COPY OF THE SAFETY DECAL
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
499
499
DOOR SEAL: Please
check that the door is
properly sealed
Minimum Clearances to Combustibles /
Dégagements minimaux par rapport aux matériaux combustibles
Serial No./ No de série
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Duplicate S/N
0" Clearance to
combustibles from:
Sides, bottom and rear of unit
Mantel Clearances from Top:
(A) Min. 12" (305mm)
Side Wall Clearance
from Side Facing
B) 6"
Alcove Clearances:
Max. Depth 36" (914mm)
Min. Width 48" (1219mm),
Min. Height 72" (1229mm)
Minimum Vent Clearances:
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/4" (32mm)
(
See Instruction Manual for detailed instructions)
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle P36E-LP11
PROPANE GAS: Model P36E-LP11
11” WC/C.E. (2.73 kPa)
10" WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Pression d'alimentation minimale
Pression manifold lev e
é é
Pression manifold basse
28,500 Btu for altitude 0 - 4500 ft.
Maximum Input
Minimum Input
Orifice size
Altitude
28,500 Btu/h (8.35 Kw/h)
22,000 Btu/h (6.44 Kw/h)
#52 DMS
0-4500 ft/pi (0-1372m)
D bit calorifique maximal
é
D bit calorifique minimal
é
Taille de l'orifice
Altitude
NATURAL GAS: Model P36E-NG11
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle P36E-NG11
Pression d'alimentation minimale
Pression manifold lev e
é é
Pression manifold basse
Taille de l’orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
5” WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0..87 kPa)
1.6" WC/C.E. (0.27 kPa)
# 37 DMS
19,500 Btu/h (5.71 kW)
29,500 Btu/h (8.65 kW)
0-4500 ft/pi (0-1372 m)
Part #: 919-979
Colour: Everything black on grey except what is highlighted is printed red.
Material: 2 ml silver matt polyester (DPM SMS)
Size: 100%
Dec 06/2018: Created decal.
Feb. 05/19: Remodeled decal + added ETL logo at the bottom
*Printer: Start serial sequence @ 499000001
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United
States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual
for details.
Fan (Part # 438-917) Option: HeatWave Kit # 946-556
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces
normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only À utiliser uniquement avec les portes en verre certifiées avec l'appareil
Made in Canada/
Fabriqué au Canada
FPI Fireplace Products International Ltd.Delta, BC, Canada
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
B
B
32"
Ceiling
W
all
W
all
A
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE:
115V_60HZ less than/moins de 2 AMP
For Use Only with Barrier (Part #515-005 with Vignette) or (Part #515-929 Installed with Louvers) Follow installation instructions.
o
Utiliser uniquement avec l’écran (n° 515-005 avec façade Vignette) ou ( n 515-929 Installation avec grilles d’aération) Suivre les consignes d'installation.
28 500 Btu pour altitude comprise entre 0 et 4500 pi
Listed:
VENTED GAS FIREPLACE HEATER/FOYER AU GAZ À ÉVACUATION
Certified to
/Certifi :
é
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
C#4001172
919-979
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 66.86%
Propane Gas / Gaz propane 67.44%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
ANSI Z21.88-2017 • CSA 2.33-2017 / CSA 2.17-2017
DECAL LOCATION
Remove the faceplate from unit (refer to
manual) the rating plate will be attached
to a black chain as shown below.
DO NOT REMOVE DECAL FROM UNIT.