P36E-10 Zero Clearance Direct Vent Gas Fireplace
|
19
19
|
installation
VENTING
DIRECT VENT SYSTEM (FLEX)
HORIZONTAL TERMINATIONS ONLY
These venting systems, in combination with the P36E Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent
Termination Locations" section.
Regency Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the P36E with a maximum
run of 4 feet.
1)
6-7/8" dia. flexible liner (4 ft. length)
2)
4" dia. flexible liner (4 ft. length)
3)
spring spacers (4)
4)
thimble (2)
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
1)
6-7/8" dia. flexible liner (10 ft. length)
2)
4" dia. flexible liner (10 ft. length)
3)
spring spacers (7)
4)
thimble (2)
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" Drill Point, Stainless
Steel (4)
If longer runs are needed, the Regency Direct
Vent system (Flex) # 946-516 includes all
the parts needed to install the P36E with a
maximum 10' run.
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
Summary of Contents for P36E-LP10
Page 59: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 59 59 parts list ...
Page 63: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 63 63 notes ...
Page 68: ......
Page 69: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 69 69 notes ...
Page 70: ...70 P36E 10 Zero Clearance Direct Vent Gas Fireplace 70 notes ...
Page 71: ......