background image

 

RC500E

  |    

59

operating instructions

copy of the lighting plate instructions

919-535

Part #: 919-535

Colours: Black on Grey,  except   

   for parts indicated as being     

   Red.

Size:              100%

                         w- 5.16"

                         h- 10.3"

                

Mar 25/15:     Created decal

        

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)  BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to the fl oor 

     because some gas is heavier than air and will settle on the fl oor.
       

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

C)   

Do not use this appliance if any part has been under water.  Immediately call a qualifi ed service 

      technician to inspect the appliance and replace any part of the control system and any 

       gas control which has been underwater.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B)   AVANT DE FAIRE FONCTIONNER

, renifl ez tout autour de l’appareil pour déceler une odeur 

      de gaz.  Renifl ez près du plancher, car certains gaz sont plus lourds que l’air et peuvent       

          

          

      s’accumuler au niveau du sol.

       

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

    • Ne tentez pas d’allumer d’appareil

    • Ne touchez à aucun interrupteur; ne vous servez pas des téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

    • Si vous ne pouvez rejoindre le fournisseur, appelez le service incendie.

C)   

N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter  l’appareil par un tech-

nicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.

DO NOT REMOVE THIS INSTRUCTION PLATE

TO TURN OFF GAS APPLIANCE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

CAUTION:  Hot while in operation. Do not touch. Severe Burns may result. Due to high surface 

temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable 

vapors  away.  Keep  burner  and  control  compartment  clean.  See  installation  and  operating 

instructions accompanying appliance.

WARNING:  If  you  do  not  follow  these  instructions  exactly, a  fire  or  explosion  may  result 

causing property damage, personal injury or loss of life. Improper installation, adjustment, 

alteration, service or maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or additional information 

consult a qualified installer, service agency or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice 

risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou 

la mort.

Tout défaut d'installation, d'ajustement, de modifi cation, de service ou d'entretien peut provo-

quer des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de 

l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémen-

taires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.

1) Ensure the Main switch is in the ON position and/or the battery holder switch is in the Remote position.
2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be 

heard from the receiver. 

3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.

4)  The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi ca-

tion) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a 

second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the 

second attempt the board will go into lock out.

The system will need to be reset as follows (after going into lock out mode):

 

a)   Wait 5 minutes - turn the system off  by  pressing the ON/OFF button on the remote.

 

b)   After approximately 2 seconds press the ON/OFF button again.

 

c)  Unit will repeat step 2.

1) S’assurer que l’interrupteur principal est sur ON et/ou que l’interrupteur du support de piles est en posi-

tion télécommande.

2)  Appuyer sur la touche ON/OFF de la télécommande et relâcher. Un bip se fera entendre depuis le récep-

teur.

3) Après environ 4 secondes, le système d'allumage produira des étincelles pendant 60 secondes pour al-

lumer le brûleur principal.

4)  L'appareil s’allume.

Remarque : Au premier allumage, le système tente d’allumer les fl ammes pendant 60 secondes. Si l’essai 

est infructueux, le système fait une pause de 35 secondes. C’est ce qu'on appelle l'étape de rectifi cation. 

Ce délai écoulé, le système tente à nouveau d'allumer les fl ammes en produisant des étincelles pendant 60 

secondes. Si les fl ammes ne s’allument toujours pas, le système se met en mode verrouillage.

 Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :

                 a)   Attendre 5 minutes et éteindre l’appareil en appuyant sur la touche ON/OFF de la télécom-

mande.

                 b)   Attendre 2 secondes et appuyer encore une fois sur la touche ON/OFF.                 

 

c) L'appareil répète l'étape 2.

1) 

Press the ON/OFF button on the remote.

2) 

If service is to be performed–you must disconnect power and shut off gas to the unit.

1)

 

Appuyer sur la touche ON/OFF de la télécommande.

2) 

 En cas d'entretien, débrancher l'alimentation électrique et couper le gaz.

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

Summary of Contents for Contura RC500E

Page 1: ... of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perform...

Page 2: ...ovide you with all the warmth and charm of a wood fireplace at the flick of a switch The model RC500E has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency ...

Page 3: ...85 S I T Valve Description 45 Opening the front glass door 46 Lower access panel removal installation 46 Front grill removal installation 47 Burner removal installation 47 Enamel panel installation 48 Conversion kit from NG to LP 49 Log set installation 51 Optional media installation 54 Optional wall thermostat 55 Manual operation no remote 55 Final check 55 Back up battery 55 Wiring diagram witho...

Page 4: ...ATION LECTRIQUE 115V_60HZ less than moins de 2 AMP É 467 F Left Side Wall Right Side Wall Horizontal F Left Side Wall Right Side Wall Vertical Pipe E 4 102mm F 50 1270mm Pipe See unit manual for Alcove Clearances B 2 50mm FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY À ER É É UTILIS UNIQUEMENT AVEC LES PORTES VITR ES CERTIFI ES ÉQUIPÉ EN USINE POUR GAZ NATUREL ÉQUIPÉ EN USINE POUR GAZ...

Page 5: ...ensions with horizontal venting gas line dimensions 40 5 16 42 19 5 16 18 13 16 478mm 490mm 1066mm 1022mm 22 13 16 579mm 1 11 16 R2 3 16 knock out 4 5 16 gas line 5 3 8 to C L base of unit 18 13 16 478mm 19 5 16 490mm 42 1066mm 17 1 4 437mm 44 1 4 1123mm 22 1 8 562mm ...

Page 6: ...llation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire...

Page 7: ...pliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being inspec...

Page 8: ... plug into battery terminals located near the gas valve Do not use both Only use the 4 AA batteries if 120 volt power is not available 3 Install 3 AAA batteries into handheld remote 4 Hold down the black reset button on the left side when facing unit until 3 beeps are heard 5 Hold down the ON OFF button on the hand held remote to code the remote to the receiver after 4 beeps are heard handheld is ...

Page 9: ...is manual first Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation Note Failure to follow the instructions could cause a malfunction of the heater which could result in death serious bodily injury and or prop ertydamage Failuretofollowthese instructions may also void your fire insurance and or warranty Note These instructions ta...

Page 10: ...te is Black Not silver as shown 1 Press the ON OFF button on the remote 2 If service is to be performed you must disconnect power and shut off gas to the unit Remote shown in Manual Mode on Hi NOTE Remotehandheldnotexactlyasshown 3 After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner 4 The unit will turn on lighting procedure Fan Operation The ...

Page 11: ...llation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosi...

Page 12: ...igure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote c...

Page 13: ... step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermos...

Page 14: ...n speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activate t...

Page 15: ... the main ON OFF switch located behindthefrontcoverplate totheOFFposition IMPORTANT The remote control system supplied with this appliance has several options for starting operatingtheappliance pleasereadthe remote control operating instructions packed with remote control to understand how to operate this remote system operation using an optional wall thermostat All Regency stoves ship with a full...

Page 16: ...d unsupervised operation To activate this function press the MODE and UP Keys at the same time fig 21 To de activate this function press the MODE and UP Keys at the same time Figure 21 LOW BATTERY POWER DETECTION Transmitter The life span of the remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the ro...

Page 17: ...handle Pull door handle forward to open door Latch Handle manual operation no remote To override the remote open the front lower door and locate the reset button Press the reset button until it beeps 3 times within 10 seconds press and hold the reset button again until a beep is heard After overriding the remote the ON OFF switch located on the lower left inside the lower front door tooltip toolti...

Page 18: ...front door then close the door 3 T he side safety screens are installed by lining up the tabs on the screen with the glass window frame The screens are held in place with magnets Completed screen install 4 Reverse steps to remove screens levelling leg adjustment 13 13 VANADI UM No 7 CHROME 1 Open up bottom door 2 Remove access panel See manual for details 3 Using a crescent wrench 10 mm adjust the...

Page 19: ...e logs must be as shown in the diagram under Log Installation Note Improper positioning of logs may createcarbonbuild upandwillalter the unit s performance which is not covered under warranty glass replacement Your stove is supplied with high temperature 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the eventthatyoubreakyourglassbyimpact purchase y...

Page 20: ...se fan motors on a regular basis by vacuuming out the fan squirrel cages around the motor and around the grills on the back of the stove IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock haz ard and should be plugged directly into a properly grounded three pro...

Page 21: ... in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection ...

Page 22: ...culating air passageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpassingthrougha livingarea wherechildrenmaycomeincontact with it 5 This appliance must be connected to the speci fied vent and termination cap to the outside of the building envelope Never...

Page 23: ...natingtheneedtouseheated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Each direct vent gas appliance must use it s own separate vent sy...

Page 24: ...ed above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public pr...

Page 25: ... be decreased if the alcove was 50 inches 20 E C D A F B 12 Max locating your gas stove When selecting a location for your stove ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation Maximum length will vary depending on vent run See complete details in this manual manufactured mobile home additional requirements...

Page 26: ...N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 46DVA 16A N A N A N...

Page 27: ... SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Termina...

Page 28: ...are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraventDirect Vent Pro SelkirkDirect Temp Ameri Vent Direct ICC Excel venting Olympia Ventis and Security SecureVent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI...

Page 29: ...r on Set 3 Vent Restrictor on Set 1 CPI MODE CPI MODE Horizontal venting Vertical venting 40 5 16 1022mm Important The IPI CPI switch on the hand held remote control transmitter must be turned to CPI Continuous Pilot Ignition at all times This will avoid nuisance pilot outages during operation of this appliance when using these venting configurations on this page See Remote manual for setup of thi...

Page 30: ...30 RC500E installation Venting Arrangements Horizontal venting No Vent Restrictor Factory Set Vent Restrictor Set 2 40 5 16 1022mm ...

Page 31: ... Two 45o elbows H H1 V H1 H V Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated Option H V H H1 A 1 Max 1 Min 3 Max B 2 Max 2 Min 5 Max C 3 Max 4 Min 6 Max D 4 Max 6 Min 7 Max E 5 Max 8 Min 8 Max With these options max total pipe length is 30 feet with min of 8 feet total ver tical and max 8 feet total horizontal Please note ...

Page 32: ...ntal Please note min 1 foot be tween90o elbowsisrequired Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet total horizontal Please note min 1 foot between...

Page 33: ...n 40 5 16 1022mm Max 2 0 6m co linear 3 3 flex pipe venting masonry chimney applications only Important The IPI CPI switch on the hand held remote control transmitter must be turned to CPI Continuous Pilot Ignition at all times This will avoid nuisance pilot outages during operation of this appliance when using these venting configurations on this page See Remote manual for setup of this IPI CPI s...

Page 34: ...nimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will ac commodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Desc...

Page 35: ...elbow Only cut the uncrimped side of pipe IMPORTANT Donotlocateterminationhoodwhereexces sive snow or ice buildup may occur Be sure to check vent termination area after snow falls and clear to prevent accidental block age of venting system When using snow blowers make sure snow is not directed towards vent termination area Adapter Trim Collar 4 ID Liner Spacer Spring Thimble Cover AstroCap Termina...

Page 36: ...dening mastic should be run around both the termination and vinyl sidingstandofftopreventwaterfromentering and to make a tight seal between the cap and the standoff 7 Stretchthe4 diameterflexlineroutfullyand get a trial fit of the liner onto the 4 diameter starter collar 8 Cut the 4 diameter flex liner to the desired size Hint leave an extra 12 to 16 of length this will make the final assembly eas...

Page 37: ...zontal Termination Kit which includes 1 6 5 8 Dia x 12 Black Pipe 1 4 Dia x 12 Aluminum Vent 1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 946 523 P AstroCap 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws Optional Components 946 206 Vinyl Siding Standoff AstroCap 946 506 P Vent Guard AstroCap Min 2 51mm clearance to rear of stove Max 12 305mm AstroCap 946 523 P...

Page 38: ...cular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall ensure that ALL vent and termination clearances see the Exterior Vent Terminal locations section will be met Ifthisisanoutsidecorner theminimumdistance between the vent and the outside corner is 6 15cm...

Page 39: ...allations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancerequirementsbetween the outer wall of the vent pipe and nearby combustible surfaces is 1 1 2 except when passingthroughawall ceiling oratthetermina tion where the use of a firestop or wall thimble reduces the required clearance t...

Page 40: ...Diagram 2 are available as well as the standard Riser Vent Follow the same in stallation procedures as used for standard Horizontal Termination NEVER install the snorkel upside down Diagram 1a Diagram 1 Diagram 2a As specified in CGA B149 Instal lation Code Local codes or regulations may require different clearances Diagram 2b NOTE For Snorkel terminations in ABOVE gradeinstallations follownationa...

Page 41: ...nstallation NOTE For best results and optimum performance with each approved vent ing system it is highly recommended to apply Mill Pac sealant supplied to everyinnerpipeconnection Failuretodo so may result in drafting or performance issues not covered under warranty Diagram 5 Diagram 6 c Before connecting the vent pipe to the vent termination slide the black decorative wall thimble cover over the...

Page 42: ...ng or performance issues not covered under warranty 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round Support Box Insure that all pipes and elbow connections are in the fully twist locked position and sealed The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installe...

Page 43: ...ges during operation of this appliance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the distance from the top end of the chimney to the bottom of the ceiling support box add 3 76mm to this measurement and cut a section of the 4 flex pipe to that length the flex should already be extended to it s nominal length 4 Pass the flex pipe down through the ...

Page 44: ...story vertical installations a Ceil ing Fire stop is required at the second floor and any subsequent floor Diagram 12 The openingshouldbeframedto10 x10 inside dimensions in the same manner as shown in diagram 9 b Any occupied areas above the first floor including closets and storage volcanicces throughwhichtheverticalventpasses must be enclosed cathedral ceilings Round Support RDS Square Support S...

Page 45: ...lat screwdriver 3 Attach manometer to IN and or OUT pres sure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON posi tion Read manometer 5 The pressure check should be carried out with theunitburningandthesettingshouldbewithin the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise wit...

Page 46: ...ulling forward 2 Locate latch behind right handle pull latch down 3 Front of latch will drop down and release door handle Pull door handle forward to open door 1 Open lower front door see above Lift lower access panel up 2 Lift lower access panel out of unit 3 Profile of lower access panel showing hook loca tions Reverse steps 1 2 to reinstall Latch Handle ...

Page 47: ...er or inner panels follow steps below to remove 1 Remove 2 screws from the front of the grill 1 Remove the front grill see above 2 Remove 3 screws in locations show below to release burner 3 Lift burner straight up to remove 2 Slide out lower plate securing the grill then lift the grill up and out 3 Reverse steps to reinstall the grill Grill Lower Plate tooltip tooltip ...

Page 48: ...ny media if already installed 4 Remove the front grill see manual 5 Remove the 3 screws holding the Burner Assembly to the firebox base Lift burner straight up and lift out to remove tooltip tooltip 9 Lift panel up off the screw and rotate to remove from the unit 6 Loosen 2 screws in locations shown below 7 Lift heat baffle up off screws and remove from unit Profile of heat baffle ip 10 Replace st...

Page 49: ...actly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified ser vice agency is responsible for the proper instal lation of this kit The installation is not proper and complete until the operation of the convert ed appliance is checked as specified in the man ufacturer s instructions supplied with the kit 7 Lift off pilot ...

Page 50: ...on will last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After this wait time the board will start a second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition after the second attempt the board will go into lock out The system will need to be reset as follows after going...

Page 51: ...Crushed Iceburg or black glass purchased separately from log set 1 3 5 2 4 6 7 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Open the front door of the unit see manual for detailed instructions 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Log 1 onto pin at the back of the burner Log 1 i...

Page 52: ...nt of Log 4 Log 1 push left side forward to touch Log 2 Log 4 install onto pins on burner Log 5 install Log 5 placement Glass crushed glass on burner Log 4 11 Install Log 5 place darker in of the log into the triangle created by Logs 1 2 3 Gently place the other end of the log onto the pin on the burner 12 Placement of Log 5 13 Important Spread the 3 4 Black Crystal glass over the burner evenly to...

Page 53: ...the notch on Log 2 and the pin locator on Log 6 should line up with the pin on Log 4 16 Install Log 7 the darker end will rest in the notch on Log 5 and the opposite end will rest on the bed of crushed glass on the burner 17 Log 7 should touch Log 3 when in position as shown below 18 Place the glowing wool on the crushed glass as shown below Note If the flame picture on the unit is not satisfactor...

Page 54: ... 2 Remove the 3 screws holding the Burner Assembly to the firebox base Lift burner straight up and lift out to remove 3 Remove the 6 log pins from the burner remove the burner and flip over remove the 6 six screws in locations shown below 4 Re install burner 5 Spread the crushed glass evenly on the burner and place the volcanic stones as shown below do not block the burner ports with the volcanic ...

Page 55: ...ausessooting orcarboningthatresultsindamagetotheexterior faciaisnottheresponsibilityofthemanufacturer back up battery In the event of a power outage the unit may be operated by a back up battery system 1 Open lower door of unit 2 Install 4 AA batteries into battery pack 3 Attach battery pack to left wall on unit near the reset switch ON OFF switch with velcro manual operation no remote To override...

Page 56: ...rical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Note 4 AA Batteries must be installed into the back up battery compartment however for this unit to operate when power is lost See b...

Page 57: ...SE COMFORT USER LAMP COMBUSTION DIAGNOSTIC AUX N L FAN BLOWER INTERFACE INTERFACE LOAD 3 15A T BLACK BROWN YELLOW ORANGE GREEN ORANGE YELLOW GREEN BATTERY HOLDER BLACK RED YELLOW YELLOW SPARK FLAME DETECT BLACK BLACK GREEN MAIN LINE FAN RESET SWITCH ON OFF SWITCH BLACK BLACK GREY GREY RED BLACK WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK Thermostat Optional Millivolt ...

Page 58: ...ote is Black Not silver as shown 1 Press the ON OFF button on the remote 2 If service is to be performed you must disconnect power and shut off gas to the unit Remote shown in Manual Mode on Hi NOTE Remotehandheldnotexactlyasshown 3 After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner 4 The unit will turn on lighting procedure Fan Operation The...

Page 59: ...taller service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Tout défaut d installation d ajustement de modification de service ou d entretien peut provo quer des blessures ou des dommages matériels Reportez vous au manuel du propr...

Page 60: ... AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 8 Each time the appliance is lit it may cause condensation and fog the glass This conden sation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place Note If you have an inc...

Page 61: ... against breakage when installingtheglass Gasketpartnumberis936 238 3 feet in total is required to complete both sides Gasket is sold per foot Glass Your Regency fireplace is supplied with high temperature 5mm Ceramic outer glass and inner glass If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers Do not use abrasive materials CAUTION WAR...

Page 62: ...62 RC500E parts list Main assembly 1 31 3 4 5 6 7 8 9 12 11 10 13 2 14 38 19 20 33 21 16 23 24 29 36 37 35 25 22 26 34 18 17 28 27 30 50 50 32 18 15 39 ...

Page 63: ...46 2 Way Gold Contact Switch 16 197067 P Replacement Glass Front Includes Gasket Black Door 16 N A Replacement Door With Glass Front Includes Gasket White Door 17 197074 P Replacement Inner Glass Sides Each Includes Gasket 18 197072 P Replacement Outer Glass Sides Each Includes Gasket 19 366 517 P Fan Assembly Complete 20 910 215 P Fan Motor Only Includes Squirrel Cage 21 945F Simpson Duravent Sta...

Page 64: ...20 Volts With Connector N S 911 209 Wire 2 Position IFC To Lights N S 911 210 Extended Antenna IFC N S 911 260 Wire 2 Position IFC Burner On Off N S 911 261 Lamp Holder G9 Halogen Light N S 910 780 Wire Red From Fan To Wire Harness N S 910 781 Wire Black From Fan To Wire Harness N S 911 175 Hand Held Remote Control GTMFL SIT 0 584 042 N S 910 692 Green Ground Wire N S W260108 Inner Flue Starter Co...

Page 65: ...s Gasket Sold Per Foot N S 366 549 Glass Clips Screws Complete Package N S 366 046 Light Socket Bracket ea N S 366 086F Air Adjustment Tool Accessories 50 366 929 Screen Guard complete set N S 366 969 Conversion Kit LP N S 366 908 Enamel panels N S 946 780 3 5 Pounds Crushed Glass Black N S 946 781 3 5 Pounds Crushed Glass Iceburg N S 946 710 Slate Grey Volcanic Stones N S 946 711 Ivory Tan Volcan...

Page 66: ... to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA FP...

Page 67: ...RC500E 67 notes ...

Page 68: ...te Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to ...

Page 69: ...lation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are ...

Page 70: ...ditional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and telephone contact ...

Page 71: ......

Page 72: ...mation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ______________________________________...

Reviews: