38
|
RC500E
installation
Pipe Length (max. 18")
Part (6-5/8" Dia)
(4" Dia.)
Decorative
Wall Trim
Horizontal
Terminal
Part# 640-530/P
Wall Thimble
(required for
combustible walls)
Vinyl Siding
Standoff (Optional)
Part #946-205
Adapter
Part #946-219/P
(required)
residential and manufactured homes / mobile homes
minimum horizontal termination installations
Planning Your venting Installation
You will require the following components with your new Regency
®
Rear Vent Direct Vent Freestand-
ing Gas Stove. Please review your product to make sure you have everything you need. In the
event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits are
available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.
Note: These are the minimum pieces required. Other parts may be required for
your particular installation.
See the "Exterior Vent Terminal Locations"
section for requirements.
The gas stove is
approved for a minimum horizontal termination
with the FPI Riser Vent Kit. See the diagram for
minimum and maximum pipe lengths.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the vent
hole through the wall ensure that ALL vent and
termination clearances (see the "Exterior Vent
Terminal locations" section) will be met.
*
If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.
NOTE:
Ensure compliance with the outside vent
terminal location before cutting hole as both dimen-
sions must be met.
Minimum components for a Horizontal Installation:
946-544
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 18" Black Pipe
1
4" Dia. x 18" Aluminium Vent
1
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
1 640-530/P Riser Vent Terminal
1
Decorative Wall Trim (Black)
1 948-128
Tube Mill-Pac
Screws
Optional Components:
946-204
45
o
Elbow - 6-5/8" Black pipe
and 4" Aluminium Vent
946-205
Vinyl Siding Shield for Riser Vent
Terminal
946-208/P Vent Guard
FPI Riser Vent
#640-530/P
Max. 15-1/2"
(394mm)
Min. 2" (51mm)
If outside corner see note * above.
*
**Min.
6-1/2"
(165mm)
A
Min. 2"
(51mm)
clearance to
rear of stove
FPI
Riser
Vent
#640-530/P
Max. 18" (457mm)
Min. 9" (229mm)
Max. 18" (457mm)
40-5/16" (1024mm)
Riser Vent Termination
When installed in a corner as shown at 2" minimum
clearance from wall to pipe using the 946-544 vent kit.
A = 5-3/4"