![Regency Contura RC500E Owners & Installation Manual Download Page 37](http://html.mh-extra.com/html/regency/contura-rc500e/contura-rc500e_owners-and-installation-manual_1433414037.webp)
RC500E
|
37
installation
Residential and Manufactured Homes / Mobile Homes
Minimum Horizontal Termination Installations
Planning Your Venting Installation
See the "Exterior Vent Terminal Locations"
section for requirements.
When planning your installation, it will be necessary
to select the proper length of vent pipe for your
particular requirements. Determine the minimum
clearance to combustibles from the rear of the unit
to the wall. It is also important to note the wall thick-
ness. Before cutting the vent hole through the wall
ensure that ALL vent and termination clearances
(Refer to the "Exterior Vent Terminal Locations"
section) will be met.
*
If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.
NOTE:
Ensure compliance with the outside vent
terminal location before cutting hole as both dimen-
sions must be met.
Minimum components for a Horizontal Installation:
380-946
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 12" Black Pipe
1
4" Dia. x 12" Aluminum Vent
1
946-202
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
1
946-523/P
AstroCap
1
640-545/P
Decorative Wall Trim (Black)
1
948-128
Tube Mill-Pac Screws
Optional Components:
946-206
Vinyl Siding Standoff (AstroCap)
946-506/P Vent Guard (AstroCap)
Min. 2"
(51mm)
clearance to
rear of stove
Max. 12" (305mm)
AstroCap
#946-523/P
Max. 12"
(305mm)
Min. 2" (51mm)
If outside corner see note * above.
*
**Min.
6-1/2"
(165mm)
A
AstroCap
#946-523/P
You will require the following components with your new RC500E Direct Vent Freestanding Gas Stove.
Please review your product to make sure you have everything you need. In the event that you are missing
any part, contact your dealer. Decorative brass or chrome trim kits are available from Simpson Dura-Vent
for their wall thimbles, as well as a square wall thimble cover.
Note: These are the minimum pieces required. Other parts may be required for your
particular installation.
Pipe Length (max. 12”)
Decorative
Wall Trim
Part #640-545/P
Wall Thimble
(required for
combustible walls)
Part #946-202
Vinyl Siding
Standoff (Optional)
Part #946-206
AstroCap
Termination Cap
(Part #946-523/P)
Kit #380-946