installation
Wiring the Unit
The wiring for the unit should be completed before any finishing material is installed.
1. Remove the right side and front right access panel--see access panel removal instructions in this manual.
2. Loosen 2 screws in locations shown below.
3. Slide electrical box plate towards the back of the unit and then out.
4. Bring the wiring from inside the wall through the opening created when the plate was removed in the previous step.
5. Wire the electrical box.
NOTE: The receptacle and receptacle cover may be located in the manual pack and may need to be installed.
6. Feed any excess wiring into the wall and reinstall the plate onto the wall of the unit.
7. Reinstall electrical box and plate onto screws.
8. Tighten screws to secure.