6
|City Series CV60E-1
safety decal
Part #:
920-546
Colour:
Black on grey except what is indicated as being printed red.
Size:
(File at 100%) 9.11"w x 6.27"h
Material:
Start serial sequence at 546000001
June 08/22:
Created draft
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
579
579
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products
International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles /
Dégagement minimaux par rapport aux matériaux combustibles
Serial No./ No de série
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed/Nom:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified to / Certifi :
é
ANSI Z21.88-2019 • CSA-2.33-2019
CSA 2.17-2017
Electrical supply / Alimentation électrique 115VAC, 2.5A, 60Hz.
Made in Canada
Fabriqué au Canada
Duplicate S/N
(
See instruction manual for detailed instructions)
(Voir manuel pour plus de détails)
GAZ PROPANE : Modèle CV60E-LP1
PROPANE GAS: Model: CV60E-LP1
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
GAZ NATUREL : Modèle CV60E-NG1
5.0" WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
# 32 DMS
39,000 Btu/h (11.42 kW)
21,000 Btu/h (6.15 kW)
0-4500 ft/pi (0-1372 m)
11" WC/C.E. (2.73 kPa)
10.5" WC/C.E. (2.62 kPa)
2.9" WC/C.E. (0.72 kPa)
# 50 DMS
36,000 Btu/h (10.54 kW)
19,500 Btu/h (5.71 kW)
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
Side Walls / Murs latéraux
A
8" (203 mm)
Ceiling / Plafond
B 52" (1321 mm)
Min. Mantel Height
/Hteur Min
Manteau
C 9" (229 mm) with 12" mantel
Max. Mantel Depth/Profondeur Max
Manteau
D
12" (305 mm)
Alcove Width/Largeur Alcôve
E
109.5" (2781 mm)
Alcove Depth/Profondeur Alcôve
F
35" (889 mm)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas
applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Une trousse de conversion est fournie avec cet appareil.
C # 4001172
For Use Only with Barriers CV60E-1 (Part #940-519/P) Follow installation instructions.
Utiliser uniquement avec l’écrans CV60E-1 (n° 940-519/P) Suivre les instructions d'installation.
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
Pression de sortie (manifold) - Basse
Taille de l’orifice
D bit calorifique maximal
é
D bit calorifique minimal
é
Altitude
Pression d'alimentation minimale
Pression de sortie (manifold) - Haute
Pression de sortie (manifold) - Basse
Taille de l’orifice
D bit calorifique maximal
é
D bit calorifique minimal
é
Altitude
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. CATEGORY I.
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE. CATÉGORIE I.
FOYER AU GAZ À ÉVACUATION -
Model/Modèle :
CV60E-NG1
CV60E-LP1
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES
2
Min. 180 in
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
D
E
F
A
B
C
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
920-546
CSA P.4.1 Fireplace Efficiency (FE) /
Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 51.22%
Propane Gas / Gaz propane 51.96%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
NATURAL GAS: Model: CV60E-NG1
Part No. 946-535 Power vent Horizontal Termination City Series may be used. La terminaison horizontale Power V ent City Series (pièce n°946-535) peut être utilisé
e
.
Part No. 666-945 Inline Power vent City Series may be used. La terminaison en ligne Power Vent City Series (pièce n°666-945) peut être utilisé
e
.
Remove the centre access panel on the outer trim. Data plate
will be next to the gas valve, as shown below.
A
DETAIL A
SCALE 1 : 12
PROCESS :
DWN:
SIGN:
E.C.N.:
DATE:
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT.
PART :
MAT'L :
UNITS IN INCHES
DIMENSIONS
0.000 = 0.01 CRITICAL
0.000 = SPECIFIED TOLERANCE
0.000 = 0.031
0.000 REF = REFERENCE ONLY
ANGULAR = 1
TOLERANCES UNLESS
OTHERWISE STATED
DO NOT SCALE
DRAWING
3RD ANGLE
PROJECTION
REV:
PART NO:
FIREPLACE PRODUCTS
INTERNATIONAL
457-500
-
CP60 MAIN ASSEMBLY
-
SHEAR/ PUNCH/ FORM
11/24/2021
DATE:
SCALE:
1:24
Decal
Decal Location
Remove
This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located
on the front inside base of the unit, visible when the outer front panel is removed.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Decal
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the
appliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.