installation
OPTIONAL WALL THERMOSTAT INSTALLATION
This installation must be completed during intial install prior to the faceplate being installed.
A wall thermostat may be installed if desired.
1)
Run wires from thermostat into the unit.
2) Remove the green wire marked (TH) at the white connector-shown below. The noted wires will be located near the gas valve.
Disconnect greenTH wire
Green Wires
White Connector
3)
Connect one thermostat lead to female connector, using male spade con-
nector - see picture below.
CAUTION
Do not wire
Thermostat wires
to 120V wire.
4)
Connect the other thermostat lead to male connector disconnected
from Step1using a female spade connector - see picture below.
When complete turn remote receiver to the ON position.
Unit will now operate using the wall thermostat.
NOTE: When the remote receiver is set to ON position, the
remote control transmitter and all of its features are now dis-
abled.