installation
FLUE COLLAR REMOVAL AND INSTALLATION & DEFLECTOR REPLACEMENT
NOTE:
The removable flue collar is attached to the unit. If you need to re-
move the collar for ease of installation, please follow the below steps.
Note: unit in images may not be identical to the I2500—but they depict the
process.
SAFETY NOTE:
The insert is very heavy and will require two people to move
it into position. The door and bricks can be removed to help. Be sure to protect
your hearth extension with a heavy blanket or cardboard during the installation.
If the combustor must be examined or replaced, follow this procedure:
1. Remove the front 3 secondary air tubes with pliers as shown below.
2. Remove baffles - push the baffles together and away from the side walls.
Note: If baffles are not installed, proceed to step 5.
4. Manoeuver the baffle above the air tube and slide out.
Side View
Front View
Front View
3. Lift the left baffle out from underneath the right baffle - then lift out. Remove
the right baffle.
Note: F2500 shown
List of Tools required:
- Tin snips
- Pull rod (supplied with unit)
- 1/2" socket / ratchet
- 3/8" open face wrench
- 7/16" socket / ratchet
6. Take a 1/2" ratchet and remove the two bolts at back inside of the firebox.
These bolts are used to secure the flue collar. Keep these and washers
for reinstall.
5. Remove locking clip from the front face of the Catalyst assembly by sliding
up and out.
7. Slide out the flue collar.
1/2" bolt
8. Install flex liner into existing chimney as per liner manufacturer’s specifi-
cations. Ensure that the notch on the adapter cut in the previous step is
pointed forward at about the 6 o'clock position. See Diagram 1.
Flex Liner
Diagram 1
Adaptor
Diagram 2
Flue Adaptor
9. Secure the adaptor to the flex liner with three screws. Ensure the adapter
is level and aligned correctly. See Diagrams 2 & 2A.
Summary of Contents for Cascades I2500