TO PREVENT POSSIBLE ELECTRICAL
SYSTEM DAMAGE OR FIRE
DO NOT TRY TO ACTIVATE
SHORE POWER MAIN BREAKERS
IF REVERSE POLARITY LIGHT IS
DISPLAYED.
WARNING
!
GFCI Outlet
Sometimes current in a circuit escapes its normal route
and
fi
nds a “ground fault”. If that vehicle ends up to be
your body and the current passes through your heart the
results could be deadly.
A ground fault interrupter or GFCI senses the difference
between the hot and neutral wire current before a fatal
dose can be conducted and in a fraction of a second cuts
the current.
The GFCI devices used in homes are normally not ignition
protected. GFCI’s used are 15 amp and are ignition
protected.
Your boat uses 120 volt receptacles. By using a GFCI as
the
fi
rst receptacle in the circuit all the receptacles down
stream on the same circuit are protected by the initial
GFCI. This is accomplished by attaching the hot wire to
the line terminal of the GFCI receptacle and the out-going
hot wire to the load terminal. The neutral wires also use
line and load terminals on the opposite side of the GFCI
receptacle.
You can identify the GFCI primary receptacle by the test
and reset breaker in the center of the device. Check the
GFCI protection monthly. If a problem develops with
the GFCI circuitry call a marine electrician to access the
situation.
The GFCI outlets are especially useful when electrical
equipment is employed such as a drill or in the bathroom
with the use of personal devices such as curlers and hair
dryers. Never use any electrical devices when puddling
water is present to prevent a possible shock hazard.
TEST
MONTHLY
TYPICAL
GFCI
TEST
RESET
GFCI’S (GROUND FAULT CIRCUIT
INTERRUPTER
The GFCI is pro-
gramed to protect a
person from line to
ground shock hazards
which could occur
from various electrical
devices operating off
of the device or recep-
tacles down stream.
It does not prevent
line to ground electric
shock, but does cut
down the exposure
time to a fraction of a
second before the de-
vice trips. It does not
protect people against
line to line or line to neutral faults. Also, it does not pro-
tect against short circuits or overloads; this is the circuit
breakers job.
All GFCI’s should be tested monthly to make sure they
and the receptacles they protect “downstream” are pro-
tecting against ground-faults.
Summary of Contents for 38 EXPRESS
Page 1: ...784027 3 2013 OWNER S MANUAL 38 EXPRESS ...
Page 29: ...11 Safety On Board NAVIGATION LIGHT RULES ...
Page 50: ...9 Rules Of The Road ...
Page 51: ...10 Chapter 3 ...
Page 67: ...16 Chapter 4 TYPICAL MAIN DC PANEL METER SWITCH FUNCTIONS CO DC VOLTS ...
Page 109: ...58 Chapter 4 TYPICAL WASTE SYSTEM TOILET BOWL ASSEMBLY EARLIER MODELS ...
Page 142: ...14 Chapter 5 AFT FORWARD SIDEWAYS DIAGONALLY ROTATE TYPICAL JOYSTICK FUNCTIONS ...
Page 243: ...38 Chapter 8 ...
Page 275: ...15 Troubleshooting TYPICAL WINDLASS ...
Page 294: ...Technical Information 12 6 38 EXPRESS TYPICAL KOHLER GENERATOR W DIGITAL REMOTE WIRING ...
Page 295: ...Technical Information 12 7 38 EXPRESS TYPICAL DECK HARNESS 1 OF 2 ...
Page 296: ...Technical Information 12 8 38 TYPICAL DECK HARNESS 2 OF 2 ...
Page 297: ...Technical Information 12 9 38 EXPRESS TYPICAL SUMP MAIN DISTRIBUTION PANEL HARNESS ...
Page 298: ...Technical Information 12 10 38 EXPRESS TYPICAL SUMP DASH HARNESS ...
Page 299: ...Technical Information 12 11 38 EXPRESS TYPICAL SALON TV HARNESS ...
Page 300: ...Technical Information 12 12 38 EXPRESS TYPICAL STEREO HARNESS ...
Page 301: ...Technical Information 12 13 38 EXPRESS TYPICAL TRIM TAB SWITCH CIRCUITRY ...
Page 302: ...Technical Information 12 14 38 EXPRESS TYPICAL BATTERY SWITCH CIRCUITRY ...
Page 303: ...Technical Information 12 15 38 EXPRESS TYPICAL GFCI CIRCUITRY ...
Page 304: ...Technical Information 12 16 38 EXPRESS TYPICAL FIRE EXTINGUISHER GROUND CIRCUITRY ...
Page 305: ...Technical Information 12 17 38 EXPRESS TYPICAL TWIN VOLVO DIESEL ENGINE FIRE EXT SHUTDOWN ...
Page 306: ...Technical Information 12 18 38 EXPRESS TYPICAL BATTERY SWITCH CIRCUITRY ...
Page 307: ...Technical Information 12 19 38 EXPRESS TYPICAL FIREWALL WIRING ...
Page 308: ...Technical Information 12 20 38 EXPRESS TYPICAL WIPER CIRCUITRY OVERVIEW ...
Page 309: ...Technical Information 12 21 38 EXPRESS TYPICAL FUSION INSTALLATION ...
Page 310: ...Technical Information 12 22 38 EXPRESS TYPICAL FUSION SUB WOOFER INSTALLATION ...
Page 311: ...Technical Information 12 23 38 EXPRESS TYPICAL FUSION ZONES ...
Page 312: ...Technical Information 12 24 38 EXPRESS TYPICAL AIR CONDITIONING INSTALLATION ...
Page 313: ...Technical Information 12 25 38 EXPRESS TYPICAL HARDTOP INSTALLATION ...
Page 314: ...Technical Information 12 26 38 EXPRESS TYPICAL SUMP LAYOUT ...
Page 315: ...Technical Information 12 27 38 EXPRESS TYPICAL PLUMBING LAYOUT ...
Page 317: ...Technical Information 12 29 38 EXPRESS TYPICAL SLING LOCATIONS ...