40
Chapter 7
PRESSURE PUMP-FRESH WATER
Your vessel features a variable speed fresh water pressure
pump. The variable speed allows for additional water
fl
ow
at peak times such as using the forward and aft showers
at one time. It is important not to operate the pump un-
less there is water in the fresh water tank. The pump is
controlled by a breaker on the main DC control panel.
Energizing the switch allows the pump to build the water
pressure in the distribution lines to 35 psi’s.
When the pump reaches a level of 35 psi the pump should
automatically shut off. If the system drops below a certain
pressure then the variable speed pump will restart. If the
pump cycles on and off with no water being used, a leak
in the water system is likely.
Periodically remove the water inlet
fi
lter and clean it.
Additional
fi
lters can be ordered through your Regal yacht
dealer or marine outlets.
Be sure to turn the fresh water pump at the main salon DC
panel off before performing any type of maintenance.
Filter
Fresh Water
Pump
TYPICAL FRESH WATER PUMP
In
Out
Summary of Contents for 38 EXPRESS
Page 1: ...784027 3 2013 OWNER S MANUAL 38 EXPRESS ...
Page 29: ...11 Safety On Board NAVIGATION LIGHT RULES ...
Page 50: ...9 Rules Of The Road ...
Page 51: ...10 Chapter 3 ...
Page 67: ...16 Chapter 4 TYPICAL MAIN DC PANEL METER SWITCH FUNCTIONS CO DC VOLTS ...
Page 109: ...58 Chapter 4 TYPICAL WASTE SYSTEM TOILET BOWL ASSEMBLY EARLIER MODELS ...
Page 142: ...14 Chapter 5 AFT FORWARD SIDEWAYS DIAGONALLY ROTATE TYPICAL JOYSTICK FUNCTIONS ...
Page 243: ...38 Chapter 8 ...
Page 275: ...15 Troubleshooting TYPICAL WINDLASS ...
Page 294: ...Technical Information 12 6 38 EXPRESS TYPICAL KOHLER GENERATOR W DIGITAL REMOTE WIRING ...
Page 295: ...Technical Information 12 7 38 EXPRESS TYPICAL DECK HARNESS 1 OF 2 ...
Page 296: ...Technical Information 12 8 38 TYPICAL DECK HARNESS 2 OF 2 ...
Page 297: ...Technical Information 12 9 38 EXPRESS TYPICAL SUMP MAIN DISTRIBUTION PANEL HARNESS ...
Page 298: ...Technical Information 12 10 38 EXPRESS TYPICAL SUMP DASH HARNESS ...
Page 299: ...Technical Information 12 11 38 EXPRESS TYPICAL SALON TV HARNESS ...
Page 300: ...Technical Information 12 12 38 EXPRESS TYPICAL STEREO HARNESS ...
Page 301: ...Technical Information 12 13 38 EXPRESS TYPICAL TRIM TAB SWITCH CIRCUITRY ...
Page 302: ...Technical Information 12 14 38 EXPRESS TYPICAL BATTERY SWITCH CIRCUITRY ...
Page 303: ...Technical Information 12 15 38 EXPRESS TYPICAL GFCI CIRCUITRY ...
Page 304: ...Technical Information 12 16 38 EXPRESS TYPICAL FIRE EXTINGUISHER GROUND CIRCUITRY ...
Page 305: ...Technical Information 12 17 38 EXPRESS TYPICAL TWIN VOLVO DIESEL ENGINE FIRE EXT SHUTDOWN ...
Page 306: ...Technical Information 12 18 38 EXPRESS TYPICAL BATTERY SWITCH CIRCUITRY ...
Page 307: ...Technical Information 12 19 38 EXPRESS TYPICAL FIREWALL WIRING ...
Page 308: ...Technical Information 12 20 38 EXPRESS TYPICAL WIPER CIRCUITRY OVERVIEW ...
Page 309: ...Technical Information 12 21 38 EXPRESS TYPICAL FUSION INSTALLATION ...
Page 310: ...Technical Information 12 22 38 EXPRESS TYPICAL FUSION SUB WOOFER INSTALLATION ...
Page 311: ...Technical Information 12 23 38 EXPRESS TYPICAL FUSION ZONES ...
Page 312: ...Technical Information 12 24 38 EXPRESS TYPICAL AIR CONDITIONING INSTALLATION ...
Page 313: ...Technical Information 12 25 38 EXPRESS TYPICAL HARDTOP INSTALLATION ...
Page 314: ...Technical Information 12 26 38 EXPRESS TYPICAL SUMP LAYOUT ...
Page 315: ...Technical Information 12 27 38 EXPRESS TYPICAL PLUMBING LAYOUT ...
Page 317: ...Technical Information 12 29 38 EXPRESS TYPICAL SLING LOCATIONS ...