4
Chapter 10
FRESH WATER SYSTEM:
1. Turn on the fresh water pump switch.
2. Open all faucets including transom shower and allow
tank to empty.
3. Drain the water heater; shut off water pump switch.
4. Mix nontoxic antifreeze with water in accordance with
the manufacturer’s recommendations.
5. Pour solution into the fresh water tank.
6. Turn on fresh water pump switch.
7. Open each cold water faucet one by one beginning
with the one furthest away from the tank and purge
the system until a steady stream flows from the faucet.
Then close the faucet.
8. Repeat step 7 for hot water faucets.
9. Shut off water pump switch.
10. Pour a quart of nontoxic antifreeze into shower
drain. Run the shower pump until a steady stream
flows from the discharge fitting.
11. Leave at least 2 gallons of antifreeze solution in the
holding tank during storage.
WASTE/TOILET SYSTEM:
1. Pump out waste holding tank, flush the tank with
fresh water and pump out again.
2. With nontoxic propylene glycol type antifreeze in
the fresh water tank, operate head until antifreeze
flows into bowl of head.
3. Operate macerator until antifreeze has a steady flow
coming from the discharge fitting. Pour nontoxic
antifreeze solution in head and flush head as needed
to winterize macerator pump.
4. Leave at least 2 gallons of antifreeze solution in the
holding tank during storage.
5. For further information see the toilet owner’s manual
in the document pouch
ELECTRIC TOILET
1. Operate the toilet in the dry bowl mode to evacuate
as much water as possible. Drain the remaining water
from the base by removing the base plug or sponge
from bottom of bowl.
2. When filling the holding tank by pumping it through
the toilet, use only ethylene glycol based antifreeze
not petroleum based anti-freeze.
There are several methods of winterization that can be
used with your AC unit. Use only 50/50 non-polluting
biodegradable antifreeze/water solution. See your AC
manual in your owner’s pouch for more information or
call your Regal dealer.
1. Open seacock and allow water to drain if boat
is out of the water. Clean out the seacock and
close it.
2. Open top of strainer and fill with antifreeze
solution.
3. Operate air conditioning pump refilling sea
strainer with antifreeze as the level goes down.
4. Continue to operate pump until antifreeze
flows out of thru-hull fitting.
5. Shut off air conditioning pump and install the
seawater strainer top.
AIR CONDITIONING:
Summary of Contents for 30 EXPRESS
Page 1: ...30 EXPRESS OWNER S MANUAL...
Page 2: ...784022 OWNER S MANUAL 30 EXPRESS 12 2012...
Page 30: ...11 Safety On Board NAVIGATION LIGHT RULES...
Page 41: ...Chapter 2 22 Notes...
Page 44: ...3 Rules Of The Road NAVIGATION RULES...
Page 85: ...28 Chapter 5 Notes...
Page 105: ...4 Chapter 7...
Page 106: ...5 Equipment Operation...
Page 107: ...6 Chapter 7...
Page 108: ...7 Equipment Operation...
Page 109: ...8 Chapter 7...
Page 110: ...9 Equipment Operation...
Page 111: ...10 Chapter 7...
Page 117: ...16 Chapter 7...
Page 126: ...25 Equipment Operation ROTARY ENCODER AND MENU KEY...
Page 127: ...26 Chapter 7 USING THE ROTARY ENCODER AND MENU KEY...
Page 158: ...57 Equipment Operation BACKING A TRAILER 1 2 3 4 LAUNCHING RAMP...
Page 161: ...60 Chapter 7 Notes...
Page 195: ...34 Chapter 8 Notes...
Page 204: ...9 Troubleshooting TOILET SYSTEM DIAGNOSTIC CHART...
Page 209: ...14 Chapter 9...
Page 219: ...6 Chapter 11 Notes...
Page 221: ...2 Chapter 12...
Page 224: ...5 Technical Information 30 Express Deck Overview 30 Express Cabin Overview...
Page 225: ...Technical Information 12 6 30 EXPRESS...
Page 226: ...12 7 Technical Information 30 EXPRESS...
Page 227: ...Technical Information 12 8 30 EXPRESS...
Page 228: ...12 9 Technical Information 30 EXPRESS...
Page 229: ...Technical Information 12 10 30 EXPRESS 30 EXPRESS...
Page 230: ...12 11 Technical Information TYPICAL NEGATIVE GROUND SYSTEM...
Page 231: ...Technical Information 12 12 30 EXPRESS...
Page 232: ...12 13 Technical Information 30 EXPRESS...