8 Electrical connections
FlexiMova
®
mm - Design and Installation
59 of 80
.
8.5.4
Description and examples of connections to the terminal
block of the control board
.
Digital inputs
The product has 6 digital inputs (DI1...DI4, DI-STO, HW-STO).
The digital inputs DI-STO and HW-STO are reserved solely for Safe-
Torque-Off function whereas the functions of the digital inputs from
DI1 to DI4 can be programmed as desired.
The digital inputs are galvanically separated, consequently the reference
ground DICOM1of the digital inputs is also galvanically separated. If using 24
V inside the converter the DICOM1 must be connected to the GND of the
digital inputs.
For this purpose a bridge must be formed between GND and DICOM1.
Relay outputs
All the relay outputs of the product are programmable.
The converter has:
2 relay outputs (NO/NC contact ) with changeover contact
Analog inputs/outputs
All the inputs and outputs of the converter are programmable.
It has:
One analog output 0-10 V / 0-20 mA / 0-100 kHz that can be programmed
with all of the product’s operating values (current, DC, voltage, speed,
frequency, estimated torque, delivered power).
Two analog inputs AN1 and AN2 that can be set in voltage mode or in
current mode.
See the Safety Manual for the correct use and connection of the DI-STO
and HW-STO signals.