8 Electrical connections
60 of 80
FlexiMova
®
mm - Design and Installation
Figure 31
: Example of connection with +24 V power supplied by the converter - total available power
MAX. 500 ma
,
MAX. 150 ma
for each output.
Configurable analog
input AIN1 and AIN2:
10‐0‐10 V/ 0‐10 V / 4‐20 mA / 0‐20 mA
-
Differential mode: only two wires AIN+ and AIN‐
-
‐Non‐differential standard mode:
Connection of GND with –AIN only for analog voltages
that are not ground‐referenced
Configurable relay output 2:
A9 = normally closed
A8 = normally open
A7 = common
24 V output available
(MAX. 150 mA)
Configurable relay output 1:
A4 = normally closed
A3 = normally open
A2 = common
Configuration analog output AO1:
0-20 mA / 4-20 mA (Default)
DIP1 OFF – DIP2 OFF
0-10 V
DIP1 OFF – DIP2 ON
0-100 kHz
DIP 1 ON – DIP 2 OFF
*Both DIP1 and DIP2 ON
Is not a recognized configuration
Cu
rre
nt
‐v
olt
ag
e
fo
rc
in
g
HW
OF
F =
v
olt
ag
e;
O
N =
cu
rre
nt
;
P11
=
A
IN
1;
P7
=
A
IN
2
Safety Stop input HW-STO
Safety feedback input DI-STO
Configurable digital inputs DI1 - DI4
Configurable analog output AO1