background image

 

M003 Issue: 1.5 Created by: Technical Dept. 

25 

February 2020 

Glossary of Terms 

 

 

CANBUS 

A vehicle bus standard designed to allow electronic control units and devices to communicate with 
each other in applications without a host computer 

CAP168 

The standards required at aerodromes relating to management systems, operational procedures, 
physical characteristics, assessment and treatment of obstacles, visual aids, rescue and fire-fighting 
services and medical services 

CFD 

Computational Fluid Dynamics 

Config 

Configuration function of a Lightbar 

DC 

Direct Current 

Default 

Preset value of a user configurable function 

Dim 

A function to reduce the full brightness of a Lightbar 

ECE R65 

United Nations standard for beacons, lightbars and other vehicle warning lamps 

F1 - F9 

Programmable Inputs 

ft/lb 

Foot-Pounds 

fpm 

Flashes Per Minute 

Gnd 

Ground 

(high current connector)

 

in/lb 

Inch-Pounds 

IP 

Ingress Protection Rating 

Inclusion Flag 

Enable/Disable programmed function as part of the flash pattern 

Kg/cm 

Kilogrammes Per Square Centimetre 

LED 

Light Emitting Diode 

mA 

Milliamps 

Nm 

Newton Meter 

Module 

Bullitt Advanced LED slave board 

Pat 

Pattern Select 

(change flash pattern of the Lightbar)

 

R65 Monitor 

A positive output to indicate that R65 is functioning 

Serial 

Serial interface connection 

Standby Mode 

Lightbar is connected to a power source & fused correctly 

S/T/I 

Stop/Tail/Indicator 

Sync 

The matching of Redtronic products to enable them to flash together 

TDIR 

Traffic Director 

Torque 

Application of force acting at a radial distance and tending to cause rotation 

+ve 

Positive 

-ve 

Negative 

V+ 

Power in positive 

(high current connector)

 

360 O/P 1 

Primary Lightbar Output 

(flash entire bar)

 

360 O/P 2 

Secondary Lightbar Output 

(programmable)

 

 

 

 

 

Summary of Contents for BULLITT ADVANCED

Page 1: ...hod to ensure customers cannot accidentally change feature settings Added information on setting up Stop Tail Indicator lamps Improved explanation of features Explanation of dipswitch settings on mast...

Page 2: ...Director Length 11 5 Enable Chase Mode 8 8 8 8 8 12 0 Additional Programmable Inputs 9 12 1 Front Rear Split 12 2 Cruise Mode 12 3 Front Flood Takedown Flash 12 4 Front Floods 12 5 Stop lamp 12 6 Tail...

Page 3: ...itt Advanced Lightbars are manufactured to operate within the voltage range of 10 30v DC negative ground ve earth This will require setting upon installation to ensure correct functionality Supply Vol...

Page 4: ...echnical Dept 3 February 2020 Standby Mode 4 0 LBAR Main Controller There are nine programmable inputs F1 F9 available to programme a variety of 23 optional features 4 1 Input Output functions 4 2 Wir...

Page 5: ...Left Right 10 Triple Mix Mode 3 Double Left Right 11 Double Mix Mode 4 Single Left Right 12 Single Mix Mode 5 Quad All On 13 Quad In Out 6 Triple All On 14 Triple In Out 7 Double All On 15 Double In O...

Page 6: ...rent flash modes left right all on mix in out In addition the colour can be individually set to each output refer to 9 0 Setting the Colour 6 1 360 1 360 2 Outputs a Ensure the Lightbar is in Standby...

Page 7: ...nce This is a positive output that will drive upto 500mA at nominal voltage supply Please do not put a heavy load to this wire connection When there is non compliance to the standard the signal will d...

Page 8: ...ft 3 F1 Main Traffic Director Left Right 4 F2 Main Traffic Director Right Centre 5 F3 Main Traffic Director Centre Rotate 6 F6 Rotate Ends Front Only 7 Flash Front Only Rear Only 8 F5 Flash Rear Only...

Page 9: ...yellow wires 11 3 Warning Lamp Mode a Ensure the Lightbar is in Standby mode b Apply the orange purple wires to ve permanently If more than one TDIR function is selected the Lightbar will resort to a...

Page 10: ...rnate the flash mode against 360 1 360 2 flexi flash or other mode if not restricted simple apply the brown Pattern Select wire to ve for five 5 seconds this will alternate the flash pattern against t...

Page 11: ...arious lamp positions at this stage with a maximum length of 1 full module the modules split into half to allow for STI setup using BL ADSTI each time it will return to the centre to allow you to sele...

Page 12: ...ection 10 1 selecting feature code 22 for Rear Worklamp b Apply the yellow sync wire to ve permanently c Apply the grey Config wire to ve permanently d Apply the brown wire to ve momentarily until the...

Page 13: ...the programmed Flexi Flash input wire to ve permanently c Apply the yellow sync wire to ve permanently d Apply the grey Config wire to ve permanently e Apply the blue Dim wire to ve permanently f Appl...

Page 14: ...M003 Issue 1 5 Created by Technical Dept 13 February 2020 Fig 1 Fig 2...

Page 15: ...m flashing whilst the Blue lights are active on 360 1 a With the Lightbar in Standby mode b Apply the relevant function wire to ve permanently for instance as 360 2 c Apply the grey wire to ve permane...

Page 16: ...s you require are possible before proceeding When carrying out any upgrade the Lightbar should ideally be de installed from the vehicle Where this is not practicable the Lightbar MUST be isolated from...

Page 17: ...by Technical Dept 16 February 2020 d Connect the module to the existing string via the 4 way connector e If the string contains four 4 or more LED modules the return connector loom on the LBAR Main C...

Page 18: ...ernal stock code S EM315WC BL a Carefully remove the M4 and M6 socket cap screws and washers from the top lenses and place to one side b Remove the top lenses and place carefully to one side Ensure th...

Page 19: ...roximately half the current shown in the table below Installers should contact their sales representative if unsure of the fusing requirements Lightbar Size Type No of LED s Flash Pattern 3 Watt Max C...

Page 20: ...tings In extreme cases it may be necessary to restore the Lightbar to factory settings a Ensure the Lightbar is in Standby mode b Apply the brown Pattern Select wire to ve permanently c Apply the blue...

Page 21: ...distance of the pressure washer nozzle from the lightbar is 15cm Ensure the water pressure does not exceed 100 bar Ensure the water flow rate does not exceed 15 litres min Ensure the water temperature...

Page 22: ...rogrammed Refer to 10 0 Programming the Lightbar to re enable excluded LED modules All LED s flash at the same time blinking CAP168 Airport mode enabled De select dipswitch 2 Change flash pattern Appl...

Page 23: ...4 F2 Main Traffic Director Right Purple 4 short flashes Centre 5 F3 Main Traffic Director Centre Pink 1 long flash Rotate 6 F6 Rotate Ends White Brown 1 long 1 short flash Front Only 7 Flash Front Onl...

Page 24: ...ODULE 10 59 93 BL ADSBN BULLITT ADVANCED 6 LED BLUE LED MODULE 10 59 93 BL ADSRN BULLITT ADVANCED 6 LED RED LED MODULE 10 59 93 BL ADSGN BULLITT ADVANCED 6 LED GREEN LED MODULE 10 59 93 BL ADSWN BULLI...

Page 25: ...ENTARY CIGARETTE PLUG 4 28 57 EM173CGD2 LATCHING LATCHING CIGARETTE PLUG 4 28 57 EM173RFSS SUPER STRONG MAGNET 10 17 86 FASTWM4ZPN M4 WASHER ZINC PLATED 100 0 13 FASTWM6CSN M6 WASHER CARBON STEEL 100...

Page 26: ...9 Programmable Inputs ft lb Foot Pounds fpm Flashes Per Minute Gnd Ground high current connector in lb Inch Pounds IP Ingress Protection Rating Inclusion Flag Enable Disable programmed function as par...

Reviews: