M003 Issue: 1.5 Created by: Technical Dept.
10
February 2020
12.6
Tail -
Factory fitted but can be installed as an upgrade (see 13.0 Lightbar Upgrades)
You must utilise 2 x BL.ADSTI for this function to work
–
setting this feature on a standard lightbar
lamp will void warranty
g)
Follow section 10.1, selecting feature code 15 for Stop
h)
Follow section 10.1, selecting feature code 16 for Tail for the wire connection to
run this feature
i)
Once set, the tail lamps should appear in the same position you have set up for
STOP.
12.7
Left Indicator
–
sets the REAR INDICATOR positions
You must utilise 2 x BL.ADSTI or 2 x BL.ADIND for this function to work as expected
–
setting this
feature on a standard lightbar lamp does not meet UNECER6 & UNECER7 homologation
requirements unless the specified lamps are utilised.
This setup procedure sets up the REAR POSITION of the Indicators in the lightbar. If you want to set
up FRONT POSITION indicators only, please see 12.8
a)
Follow section 10.1, selecting feature code 17 for Indicator Left
b)
The lamps at the rear should light up REAR CENTRE INDICATOR positions (Front
indicators will light up if active)
c)
Apply the yellow
(sync)
wire to
-ve permanently
d)
Apply the grey
(Config)
wire to +ve permanently
e)
Apply the
brown
wire to +ve momentarily until the required module sections are lit
–
you can cycle through various lamp positions at this stage
–
with a maximum length of
1 full module
–
the modules split into half to allow for STI setup using BL.ADSTI, each
time it will return to the centre to allow you to select the correct position -
the ‘off’
position is a part of this setup procedure, so if you do
not want ‘REAR INDICATORS’
leave the lamps in the ‘off’ position in order to ensure no lamps light up upon
activating an indicator line
f)
This is setting the REAR position
–
so depending on how the lightbar is already set up,
some front lamps may be lit
–
in order to turn these off, you need to set up
Right
Indicator
–
see 12.8
g)
Once setup in the correct position: Release the grey and yellow wires
12.8
Right Indicator -
sets the FRONT INDICATOR positions
You must utilise 2 x BL.ADSTI or 2 x BL.ADIND for this function to work as expected
–
setting this
feature on a standard lightbar lamp does not meet UNECER6 & UNECER7 homologation
requirements unless the specified lamps are utilised
a)
Follow section 10.1, selecting feature code 18 for Indicator Right
b)
If you already set up the LEFT INDICATOR then the position will already be set
–
if not,
please follow section 12.7
c)
You may find that the FRONT INDICATOR positions are lit
–
these can now be turned
off using the following procedure:
d)
Apply the yellow
(sync)
wire to
-ve permanently
e)
Apply the grey
(Config)
wire to +ve permanently
f)
Apply the
brown
wire to +ve momentarily until the required module sections are lit on
the FRONT of the lightbar
–
you can cycle through various lamp positions at this stage
–