Ellipse
INSTALLATION GUIDELINES
70-00159-01-09
Proprietary Redline Communications © 2015
Page 12 of 52
April 29, 2015
for electrical grounding and safety. Failure to meet safety requirements and/or use of
non-standard practices and procedures may result in personal injury and/or damage to
equipment.
The system must be properly grounded to protect against power surges and
accumulated static electricity. The user is responsible to install this device in accordance
with the local electrical codes: correct installation procedures for grounding the unit,
mast, lead-in wire and discharge unit, location of discharge unit, size of grounding
conductors and connection requirements for grounding electrodes.
All outdoor wireless equipment is susceptible to surge damage from a direct hit or
current induced from a near strike. A direct lightning strike may cause serious damage
even if recommended guidelines are followed. Installing surge protection and following
grounding practices detailed in local and national electrical codes can minimize
equipment damage, service outages, and chance of serious injury.
The major reasons for surge damage can be summarized as:
Poorly grounded antenna sites
Improperly installed surge protection equipment
A lighting protection system provides a means by which the energy may enter earth
without passing through and causing damage to parts of a structure. A good grounding
system disperses most of the surge energy from a lightning strike away from the building
and equipment. Improperly grounded connections are a source of noise that can cause
malfunctions in sensitive equipment. The remaining energy on the Ethernet cable shield
and conductors can be directed safely to ground by installing a surge arrestor in series
with the cable. A surge protection system does not prevent lightning strikes, but protects
equipment by providing a low resistance path for the discharge of energy safely to
ground. If surge protection is required for the system, the following general industry
practices are provided as a guideline only:
The AC wall outlet ground for the indoor POE adapter should be connected to the
building grounding system.
Install a surge arrestor in series with the Ethernet cable at the point of entry to the
building. The grounding wire should be connected to the same termination point
used for the tower or mast.
Provide direct grounding connections from the RDL-3000 system, the mounting
bracket, and the antenna to the common building ground bus. Use the grounding
screws provided for terminating the ground wires.
L
’installation exige aussi que l’appareil soit branché à un parafoudre qui répond à
toutes les normes nationales de sécurité.
1.4
WEEE Product Return Process
In accordance with the WEEE (Waste from Electrical and Electronic Equipment)
directive, 2002/96/EC, Redline Communications equipment is marked with the logo
shown below. The WEEE directive seeks to increase recycling and re-use of electrical
and electronic equipment. This symbol indicates that this product should not be disposed
of as part of the local municipal waste program. Contact the local sales representative
for additional information.
Figure 1: Notice: WEEE Logo