background image

 

 

 

Installation Kit 

 
 

Kit includes:

 

 
 

 
 
 
 

Warning:

  Removal of the wired screws and lead seal 

(16)

 from the valve body 

(7)

 will 

destroy  the  pressure  relief  calibration  and  void  the  warranty!    If  service  to  the  valve 
assembly  effecting  calibration  is  required,  it  must  be  returned  to  manufacturer  for 
service. 

 
 
 

Field Provided Items 

 
Items to be supplied by installer: 
(see Figure 2 on page 8) 
 
 

  Pipe & Flexible Metal Connection 

(33)

  

 

  Pipe Fittings 

 

  Drip leg 

(31)

 with Drain Port 

(38)

   

 

  ¼” line 

(37)

 to connect Valve Body water  

 

     drain hole 

(24)

 to Drip Leg 

(31)

  

 

 

  A two inch (2”) Female NPT Pipe Union 

(12)

  

             (see Figure 2 on page 8)

 

 

  Materials for providing supplemental support of 

 

     valve (3/4” iron pipe) 

 
 

 

 

 

 

 

 

 

 

  

      

Typical Installation

 

 

  One (1) Pre-assembled RS-2 

RuptureSeal

™ 

     which includes:  

  3 O-rings 

(1)

,

 (2) 

&

 (3)

 

  Eight (8) 1/4” Stainless Steel Cap Screws

 (4)

 

  One (1) Collection Trap Chamber Cover

 (5)

 

  One (1) Carbon Fragment Collection Trap Canister Insert 

     with Special Tack   Compound

 (6)

 

  One (1) Tee Connection

 (14)

 with plug 

  One (1) Tell-Tale Pressure Gauge 30” Hg - 0-30 psig

 (21)

 

  One (1) Double Check Pressure Equalizing valve

 (22)

 with Filter/Vent 

(34)

 

  One (1) Installation Operation & Maintenance Manual 

NOTE:

 

See Figure 
3 on Page 9 
for location 
of parts on 
assembled 
unit. 

Chiller

 

Summary of Contents for RuptureSeal RS-2

Page 1: ...umbers 5 577 389 5 644 930 for Low Pressure Centrifugal Chillers R 11 R 113 R 123 Manufactured in accordance with ASHRAE Guideline 3 1990 Sec 4 6 Flow Tested per ASME Standards Redi Controls Inc Insta...

Page 2: ...as of April 15 1996 This Copy was Printed as of February 4 2005 1994 INDIANAPOLIS SPECIALTY VALVE INC IND PLS IN This product is marketed and sold by Redi Controls Inc under license from Indianapolis...

Page 3: ...tal Mounting Support 9 Double Check Pressure Equalizing Valve 10 Chillers utilizing R 123 special piping instructions 10 Leak Testing Procedure 10 MAINTENANCE 11 Following a Rupture 11 Annual 11 Servi...

Page 4: ...equipment Warnings may appear in this manual or on the equipment Heed all Warnings Cautions are designed to alert you to situations that may result in damage to your equipment Personal safety and the...

Page 5: ...re disks used on low pressure 15 psi or below centrifugal chillers The primary function of the RuptureSeal is to minimize refrigerant loss to the atmosphere in the event of a burst rupture disk The Ru...

Page 6: ...rain hole 24 to Drip Leg 31 A two inch 2 Female NPT Pipe Union 12 see Figure 2 on page 8 Materials for providing supplemental support of valve 3 4 iron pipe Typical Installation One 1 Pre assembled RS...

Page 7: ...e negatively affected Each installation must have such factors taken into consideration For reference see ASHRAE Guidelines relating to piping after a rupture device Warning DO NOT install an RS 2 Rup...

Page 8: ...how much of the existing rupture disk vent piping will have to be removed to accommodate the RuptureSeal Cut out and remove this section of piping 4 It is recommended that you utilize a flexible metal...

Page 9: ...t collection trap inlet 7 Valve body 24 Valve Body water drain hole 16 Calibration locking screws and seal Figure 3 Cutaway View Pressure Gauge and Auxiliary Alarm The pressure gauge 21 between the ru...

Page 10: ...ing Procedure Caution DO NOT use this procedure if chiller is at a pressure lower than 15 Hg Otherwise accidental bursting of the rupture disk could occur by imploding the rupture disk into the chille...

Page 11: ...ews 9 then lift the valve body 7 from the valve neck 32 4 Inspect the valve seat O Ring 1 and the valve body O Ring 2 If there are signs of wear or excessive compression set replace the O Rings Lightl...

Page 12: ...sure the Double Check Pressure Equalizing Valve is pointing straight up toward the sky and is unobstructed regardless of the RS 2 valve s position The Double Check Pressure Equalizing Valve only func...

Page 13: ...aporator The measurement to the immediate right of the evaporator s diameter indicates the Maximum Length of the chiller vessel evaporator that the Model RS 2 RuptureSeal valve can be installed on aft...

Page 14: ...ls are used within 20 feet 6 1 m of a pressure vessel multiply the value of f by 2 5 REFRIGERANT VALUE OF f When used on the lowside of a limited charge cascade system R 170 R 744 R 1150 1 0 0 082 R 1...

Page 15: ...ody rotated 90 degrees Rotate 2 Valve Body rotated 270 degrees Rotate 4 Valve Body rotated 180 degrees Rotate 3 Turning the carbon fragment collection trap chamber 10 and rotating the valve body 7 The...

Page 16: ...f there is a rupture all of the carbon fragments of the disk will be projected straight into the RuptureSeal carbon fragment collection trap Chiller Chiller Chiller Chiller Preferred Installation 1 Pr...

Page 17: ...S DCV1 O Ring type sizes Valve seat O Ring Parker 2 133 V747 75 Valve body O Ring Parker 2 145 N674 70 Collection chamber flange O Ring Parker 2 235 V747 75 All other parts of the valve are internal a...

Page 18: ...ions provided by REDI CONTROLS Failures of equipment due to abuse accident or negligence Damages from or part failures due to equipment not being installed per REDI CONTROLS instructions per applicabl...

Reviews: