13
- Add oli
SAE 90
right up to the level of the control screw (3).
- Screw on filler screw with new gasket.
Oil change for the hydraulic tank (according to requirements)
- Unscrew the filling nozzle (1A).
- Release the suction hose (2A) and drain off the oil.
- Screw the suction hose back into place.
- Top up with
Bio-Hydraulic oil CG 46
until the level reaches the centre of the
viewing window (3A).
- Screw the filling nozzle back on.
Please note:
!
This is a closed hydraulic circuit. In order to prevent the
ingress of contaminants, the runback filter (4A) must be
replaced every 100 operating hours.
Parts list
RINK 1005/ 1010
( Only most important parts are mentioned)