PROGRAMMING THE PRESETS, SCALE FACTOR, &
OUTPUT TIME DELAYS (Cont’d)
The preset level is changed in the same way as the scale
factor. Pressing the
“P” (1)
key will display the present
value of preset 1.
To change the value, merely cycle the digits through as
you have done before. The presets can be selected from
-999999 to +999999.
The new value will be entered when the “E” key is
pressed.
(The display will blank for a short duration of time
and then re-display the count value.)
The Scale Factor value will have a direct effect on the
preset being entered. For scale factors greater than one, the
preset should be an integer multiple of the scale factor. If it is
not, the Gemini will automatically adjust the preset value up
or down to force it to be evenly divisible by the scale factor.
A time delay is changed by entering a two-digit function
code. The display will then immediately show the present
time delay in seconds with a two decimal place accuracy.
The time delay values can be set from .01 to 599.99 seconds.
To change output 1 time delay, enter function code 53 and
enter the new value by holding down or repeatedly pressing
the key below the digit position you wish to change.
The new value will be entered when the “E” key is pressed
and the display will immediately return to the count value.
Note: A time delay value of zero cannot be programmed into the Gemini. If a
value of 0 is entered into the display and the “E” key is pressed, the unit will
continue to use the previous time delay value.
As with the other functions, you must press “E” to record the changes. For the
data entry modes, if you do not press the “E” key, a time out of 5 seconds occurs,
then the display returns to operating mode without any change to the value. The
only time any change will occur is when the “E” key is pressed. As in all other
modes, the reset button is always active if enabled. Pressing
“R”
will abort the
data entry and reset the instrument.
–4–
Summary of Contents for GEMINI 1000
Page 33: ...GEMINI 1000 BLOCK DIAGRAM...
Page 34: ...GEMINI 2000 BLOCK DIAGRAM...
Page 39: ...GEMINI 1000 CONNECTIONS CONFIGURATION SWITCH SET UPS FOR VARIOUS SENSOR OUTPUTS SEE NOTE 5...
Page 40: ...GEMINI 2000 CONNECTIONS CONFIGURATION SWITCH SET UPS FOR VARIOUS SENSOR OUTPUTS SEE NOTE 5...
Page 53: ...APPENDIX F GEMINI 1000 PROGRAMMING CHART CARD...
Page 54: ...APPENDIX F GEMINI 1000 PROGRAMMING CHART CARD...
Page 55: ...APPENDIX F GEMINI 2000 PROGRAMMING CHART CARD...
Page 56: ...APPENDIX F GEMINI 2000 PROGRAMMING CHART CARD...