GEMINI 2000 SENSOR INPUT CONNECTIONS & INPUT CONFIGURATION SWITCH SET-UP
The accompanying diagram shows the details of the count Input A and
magnetic pickup circuit. The schematic circuit for Input B is almost identical to
that of Input A, with the exception that Input B does not have the Magnetic
Pickup circuitry paralleled with it. The four switches used to set up Input A and
the Magnetic Pickup are designated S1, S2, S3, and S4. To set up Input B; use
switches S5, S6, and S7. The functions of these switches are as follows:
S1 - MAG:
Enables the Magnetic Pickup terminal to be used.
LOGIC:
Disables the Magnetic Pickup Input.
Note: SWITCH S2 MUST BE IN THE “SNK” POSITION FOR
MAGNETIC PICKUP INPUT.
S2 - SNK:
Provides a 7.8 K pull-up resistor for sensors with sinking
outputs.
SRC:
Provides a 3.9 K pull-down resistor for sensors with sourcing
outputs.
S3 - HI FRQ:
Removes damping capacitor and allows operation up to 10
KHz. Minimum count ON/OFF times - 50 usec.
LO FRQ:
Connects damping capacitor for switch contact debounce.
Limits count speed to 100 cps max. Min. count pulse ON/OFF time - 5
msec.
S4 - HI BIAS:
Sets input trigger levels at mid-range to accept outputs from
2-wire proximity sensors, resistive photo-cells, and logic pulses with
full 0 to +12 V swings. (V
IL
= 5.5 V, V
IH
= 7.5 V)
LO BIAS:
Sets input trigger levels to the low range to accept logic
pulses with 0 to 5 V swings. (V
IL
= 1.5 V, V
IH
= 3.75 V)
S5 -
Same as S2, for Input B - does not affect Magnetic Pickup Input.
S6 -
Same as S3, for Input B.
S7 -
Same as S4, for Input B.
S8 - DIS. RST.:
Disables front panel reset.
EN. RST.:
Enables front panel reset if
“Operator Accessible
Functions”
mode
(Code 66)
has Reset enabled.
–40–
CHAN.
B
CHANNEL
A
Summary of Contents for GEMINI 1000
Page 33: ...GEMINI 1000 BLOCK DIAGRAM...
Page 34: ...GEMINI 2000 BLOCK DIAGRAM...
Page 39: ...GEMINI 1000 CONNECTIONS CONFIGURATION SWITCH SET UPS FOR VARIOUS SENSOR OUTPUTS SEE NOTE 5...
Page 40: ...GEMINI 2000 CONNECTIONS CONFIGURATION SWITCH SET UPS FOR VARIOUS SENSOR OUTPUTS SEE NOTE 5...
Page 53: ...APPENDIX F GEMINI 1000 PROGRAMMING CHART CARD...
Page 54: ...APPENDIX F GEMINI 1000 PROGRAMMING CHART CARD...
Page 55: ...APPENDIX F GEMINI 2000 PROGRAMMING CHART CARD...
Page 56: ...APPENDIX F GEMINI 2000 PROGRAMMING CHART CARD...