APPENDIX “D” - GEMINI FUNCTION COMMAND CODE SUMMARY (Con’t)
–48–
CODE
MODE
DESCRIPTION
COMMENTS
54
OUTPUT 2 TERMINATION (Con’t)
+/-5
Terminate after Output 2 Time Delay
+/-6
Boundary
Automatically selects [51 1].
55
NA
OUTPUT 2 TIME DELAY (Gemini 2000 Only)
Range 0.01 to 599.99 sec.
61
RIGHT-HAND DUMMY ZEROS
1
1 Dummy Zero
2
2 Dummy Zeros
3
3 Dummy Zeros
4
No Dummy Zeros
63
SAMPLE TIME IN SECONDS (rate only)
1
1
2
2
3
5
4
10
5
20
6
50
66
“OPERATOR ACCESSIBLE FUNCTIONS” MODES
“PGM DIS” Terminal connected to “COMM.”
-
(+) Reset Button & “RST” Terminal Enabled
Front panel reset can be independently disabled by using DIP switch.*
-
(-) Reset Button & “RST” Terminal Disabled*
Both front panel and rear terminal are disabled
+/-1
No Functions Enabled
+/-2
Preset Programming Enabled
+/-3
Scale Factor Programming Enabled
+/-4
Preset & Scale Factor Programming Enabled
P(1)
NA
PRESET 1
Up to +/-999999
P(2)
NA
PRESET 2
SF(3)
NA
SCALE FACTOR
Up to +/-5.9999
*
Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.
Summary of Contents for GEMINI 1000
Page 33: ...GEMINI 1000 BLOCK DIAGRAM...
Page 34: ...GEMINI 2000 BLOCK DIAGRAM...
Page 39: ...GEMINI 1000 CONNECTIONS CONFIGURATION SWITCH SET UPS FOR VARIOUS SENSOR OUTPUTS SEE NOTE 5...
Page 40: ...GEMINI 2000 CONNECTIONS CONFIGURATION SWITCH SET UPS FOR VARIOUS SENSOR OUTPUTS SEE NOTE 5...
Page 53: ...APPENDIX F GEMINI 1000 PROGRAMMING CHART CARD...
Page 54: ...APPENDIX F GEMINI 1000 PROGRAMMING CHART CARD...
Page 55: ...APPENDIX F GEMINI 2000 PROGRAMMING CHART CARD...
Page 56: ...APPENDIX F GEMINI 2000 PROGRAMMING CHART CARD...