GENERAL DESCRIPTION

The Model C48 Counter is available as a Standard Counter or a Batch 

Counter. The Standard Counter is available with single or dual presets. The 

Batch Counter has a main process counter with dual presets and a secondary 

counter with a single preset. The secondary counter can be selected to function 

as a batch or a total counter.

The C48C features a 7 segment, 2 line by 6 digit reflective or backlit LCD 

display. For the backlit versions, the main display line is red and shows the 

count value. When preset 3 or output 3 is viewed in the secondary display, the 

batch/total value is viewed in the main display. The smaller secondary display 

line is green and can be used to view the prescaler value, preset values, output 

time values or batch/total count values (Batch model).

The C48C offers a choice of nine programmable counting modes for use in 

applications requiring bi-directional, anti-coincidence, and quadrature counting. 

The unit may be programmed to register counts on both edges of the input signal 

providing frequency doubling capability. DIP switches are used for input 

configuration set-up and to provide a Program Disable function.

Four front panel push-buttons are used for programming the operating modes 

and data values, changing the viewed display, and performing user programmable 

functions, i.e. reset, etc. The C48C can be configured for one of two numeric 

data entry methods, digit entry or automatic scrolling. The digit entry method 

allows for the selection and incrementing of digits individually. The automatic 

scrolling method allows for the progressive change of one through all digit 

positions by pressing and holding the “up” or “down” button.

The C48 Counter has programmable User Inputs and a programmable front 

panel function key. The user inputs can be configured as sinking (active low) or 

sourcing (active high) inputs via a single plug jumper. The following functions 

are available for user inputs and the front panel function key.

The Program Disable DIP switch, a user-programmable code value, an 

external user input (selected for Program Disable), and the Accessible value 

parameters can all be utilized to provide multi-level protection against 

unauthorized changes to data values and unit configuration.

The Standard Counter with dual presets is available with solid-state or relay 

outputs. The single preset model has a solid-state and relay output. The Batch 

Counter has relay outputs for Output 2 and the Batch/Total Output (3), with 

Output 1 available as solid-state. The Batch Counter is also available with three 

solid-state outputs. For all C48 Counters, the solid-state outputs are available in 

a choice of NPN current sinking or PNP current sourcing, open-collector 

transistor outputs. All relay output boards are field replaceable.

A Prescaler Output model is available as a dual preset, with solid-state 

outputs. The Prescaler Output is useful for providing a lower frequency scaled 

pulse train to a PLC or another external totalizing counter. The Prescaler Output 

provides an output pulse for every count, or every 10 counts registered on the 

display.

Optional RS485 serial communication capabilities allow for interrogation 

and modification of the preset, count, and prescaler values.

The unit is constructed of a lightweight, high impact plastic case with a 

textured front panel and a clear display window. The front panel meets NEMA 

4X/IP65 specifications for indoor use, when properly installed. Multiple units 

can be stacked horizontally or vertically. Modern surface-mount technology, 

extensive testing, plus high immunity to noise interference makes the C48 

Counters extremely reliable in industrial environments.

Safety Summary

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators 

not equipped with safeguards. To do so, can be potentially harmful to persons 

or equipment in the event of a fault to the unit.

-1-

Reset

Print Request

Store and Reset

Change Display

Program Disable

Count Inhibit

Store

Reset Outputs

Summary of Contents for C48C

Page 1: ...THE 1 16 DIN COUNTERS MODEL C48C INSTRUCTION MANUAL...

Page 2: ...on and control requirements The C48C unit which you have purchased has the same high quality workmanship and advanced technological capabilities that have made Red Lion Controls the leader in today s...

Page 3: ...ersions C48CXX1X 7 Serial Communication Wiring 8 User Inputs 8 Output Wiring 8 Input A and Input User B 8 Various Sensor Output Connections 10 FRONT PANEL DESCRIPTION 11 Keypad Functions 11 BASIC OPER...

Page 4: ...cess Preset Values 22 Preset 1 Value 22 Preset 2 Value Dual Preset Batch Models only 22 Preset 3 Value Batch Model only 22 Preset 1 Track Preset 2 Dual Preset Batch Models only 22 Access Output Time V...

Page 5: ...Chart 28 User Settings Chart 29 RS 485 SERIAL COMMUNICATIONS 30 Communication Format 30 Sending Commands and Data 30 Receiving Data 32 Serial Connections 33 Terminal Descriptions 33 Troubleshooting S...

Page 6: ......

Page 7: ...d for Program Disable and the Accessible value parameters can all be utilized to provide multi level protection against unauthorized changes to data values and unit configuration The Standard Counter...

Page 8: ...CIRCUITRY HI LO BIAS SNK SRC HI LO FREQ SW7 PROGRAM DISABLE SOLID STATE PNP CURRENT SOURCING OUTPUT S VSRC SOLID STATE NPN CURRENT SINKING OUTPUT S RELAY OUTPUT S N O USER INPUT 1 INPUT A INPUT USER B...

Page 9: ...izontal stacking the panel latch screws should be at the top and bottom of the unit The minimum spacing from center line to center line of units is 1 96 49 8 mm This spacing is the same for vertical o...

Page 10: ...rom the panel first loosen the panel latch screws Insert flat blade screwdrivers between the panel latch and the case on either side of the unit so that the latches disengage from the grooves in the c...

Page 11: ...oard connectors Be certain connectors are fully mated 4 Connect the bezel display board assembly by guiding the board ends into the bezel latches Slide the assembly on evenly until the display board c...

Page 12: ...L0000 6 To protect relay contacts that control inductive loads and to minimize radiated and conducted noise EMI some type of contact protection network is normally installed across the load the contac...

Page 13: ...AC respectively Output Power For DC Low Voltage AC units that do not have PNP current sourcing outputs Terminal 10 DC OUT VSRC IN provides a DC output for sensor power 12 VDC 15 The maximum sensor cur...

Page 14: ...s instructions for installation Note Snubber leakage current can cause some electro mechanical devices to be held ON Input A and Input User B Input A and Input B have identical circuitry and share the...

Page 15: ...alues 10 when the counter voltage at the DC OUT IN terminal is 12 VDC These typical values will vary in proportion to the variations in DC OUT IN terminal voltage caused by line voltage and load chang...

Page 16: ...C COUNT ON TURN ON CURRENT SINK CONNECTED COUNT ON CLOSING INTERFACING WITH CMOS CIRCUITRY B TYPE NOTES 1 SENSOR VOLTAGE AND CURRENT The DC OUT IN terminal can supply 12 VDC 100 mA max within a 15 ra...

Page 17: ...key is used as a quick reference for the operator if the function key is selected for a reset function This key is used to access programming enter changes to data values and scroll through the avail...

Page 18: ...grammable automatic reset modes The batch counter displays the number of process cycles that have been completed The total count is the total number of counts that have been received since the total w...

Page 19: ...P 124 200 PRS 300 3 250 124 250 CodE 000 2 PRS Prot VALuES 1 000100 PrESEt PRS 1 t 010 OutPut 2 PScALr OutPut 999999 3 Prot SAVE CodE Error 00002 PrESEt PRS 2 0 OutPut key held for 2 seconds Cnt 1 Cnt...

Page 20: ...ERMINAL PROGRAM CODE NUMBER PROTECTED VALUE MENU OPERATOR ACCESS AT MAIN DISPLAY PROGRAM DISABLE LEVEL PROGRAMMING ENABLED OFF INACTIVE or Not Programmed for Pro dis ALL No All displayed values change...

Page 21: ...key will allow changing of the value The two methods for changing numeric data values are digit entry and auto scrolling Digit Entry If the data entry method has been set to digit entry the least sig...

Page 22: ...input the display changes by 1 The prescaler value selected will affect the maximum count rate See Appendix B Specifications page 39 It is important to note that the precision of a counter applicatio...

Page 23: ...ermined by the logic state of Input B A high level at Input B causes the unit to count in a positive direction A low level causes the unit to count in a negative direction AD SUB This mode effectively...

Page 24: ...puts A and B to be counted This results in a resolution four times greater than in the basic quadrature X1 mode Counter 1 Operating Mode The charts on the following pages show operating modes for sing...

Page 25: ...4 Manual Reset to Zero 01 off at 02 02 Latched 5 Manual Reset to Zero 01 off at 02 02 Timed 6 Manual Reset to Preset 2 Latched Outputs 7 Manual Reset to Preset 2 01 Timed 02 Latched 8 Manual Reset to...

Page 26: ...ET TYPE Auto RESET To Zero To Preset 2 at Timed 02 End OUTPUT 1 Latched Timed O1 Off at O2 OUTPUT 2 Latched Timed 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 MODE Reversed Count Direction Up Dn Up Dn...

Page 27: ...med output 3 end Manual Counter can only be manually reset by a User Input or by Serial Communications command Reset to Zero When reset manually or automatically counter 2 goes to zero Output 3 is tri...

Page 28: ...ls only This parameter configures whether or not the Preset 1 value tracks or follows the Preset 2 value PRS PRS PRS PRS 2 PRS 3 PRS 2 PRS 1 MODE DESCRIPTION Locked Preset is not viewable at main disp...

Page 29: ...Output 3 Time Value controls the Output 3 duration when Output 3 is set for timed mode of operation parameter The Output time value range will be 0 01 99 99 Seconds or 0 1 999 9 seconds depending on...

Page 30: ...er up Previous State For latched output modes only The output will power up in the state it was in at power down For non latched modes the output will power up in the off state User Input State Source...

Page 31: ...ntary reset Reset All Level Active Batch model Only When the user input is activated the Counter 1 and Counter 2 values and outputs will reset and be held reset until user input is released Change Dis...

Page 32: ...400 Baud Even Parity 7 data bits 4800 Baud No Parity 8 data bits 4800 Baud Odd Parity 7 data bits 4800 Baud Even Parity 7 data bits 9600 Baud No Parity 8 data bits 9600 Baud Odd Parity 7 data bits 960...

Page 33: ...Only This parameter determines the Prescaler Output Pulse width The Prescaler Output activates on falling edges of the count signal Once activated the Prescaler Output Pulse will remain activated for...

Page 34: ...P STATE USER INPUTS USER INPUT 1 USER INPUT 2 USER INPUT B USER F1 KEY PROGRAMMING CODE VALUE SCROLL DISPLAY SERIAL BAUD RATE PARITY SERIAL UNIT ADDRESS ABBREVIATE SERIAL MNEMONICS PRINT OPTIONS PRINT...

Page 35: ...ATE SERIAL MNEMONICS SERIAL UNIT ADDRESS SERIAL BAUD RATE PARITY RS 485 SERIAL OPTION DUAL PRESET BATCH MODELS ONLY SCROLL DISPLAY PROGRAMMING CODE VALUE USER F1 KEY USER INPUT B USER INPUT 2 USER INP...

Page 36: ...be programmed to the same baud rate and parity as the connected equipment In addition the loop address number and print options should be known When used with a terminal or host computer and only one...

Page 37: ...ll units on the line after a transmit value or print request command is sent to a specific unit on the line The C48C will require a maximum of 50 msec to process the asterisk The command string is con...

Page 38: ...f transmission from a print request to provide separation between print outs If serial is abbreviated just numeric data is sent with no time delay If the C48C transmits mnemonics there is a 400 msec b...

Page 39: ...eck to make sure that the computer or device is configured with the same communication format as the C48C The communication format the C48C will accept is 1 start bit 7 or 8 data bits no parity or 1 p...

Page 40: ...85 OPTION 50 60 HZ 9VA B 1 2 14 13 A 85 250 VAC INPUT A USER INPUT 1 6 7 RS 485 OPTION 3 USER 5 4 12 11 AC AC B 1 2 13 14 A INPUT USER B 8 DC OUT IN 10 COMM 9 USER INPUT 1 INPUT A 6 7 O2 SS INPUT 2 O3...

Page 41: ...lication s Max Input Frequency 2 0 5 As a rule the counter connected to the prescaler output should be able to accept a count rate at or higher than the Effective Prescaler Output Frequency 35 Example...

Page 42: ...ft The C48CB was ordered with the RS 485 serial communication option Future plans include a data acquisition program to interrogate the C48CB s A 100 ppr rotary pulse generator is shaft coupled to a 4...

Page 43: ...37 locked PRS1 value 0 25 less than PRS2 for slow down PRS2 cut length PRS3 set high so output does not activate 1t 2t 3t APPLICATION PROGRAMMING...

Page 44: ...EMORY Nonvolatile E2PROM retains all programmable parameters and count values 4 SENSOR POWER 12 VDC 15 100 mA max 5 COUNT INPUTS A B Accepts count pulses from a variety of sources DIP switch selectabl...

Page 45: ...00001 9 0 6 1 2 1 8 2 4 1 1 2 2 7 00001 8 0 6 1 3 2 2 8 1 3 2 7 6 00001 7 0 7 1 4 2 2 3 2 1 4 2 9 5 00001 6 0 8 1 7 2 5 3 8 1 7 3 4 4 00001 5 1 2 2 8 4 4 2 4 1 3 00001 4 1 3 2 5 3 4 5 2 2 4 5 2 00001...

Page 46: ...he count speed rate 9 RS485 SERIAL COMMUNICATIONS Optional Up to 32 units can be connected Baud Rate Programmable from 1200 to 9600 baud Address Programmable from 0 to 99 Data Format 10 Bit Frame 1 st...

Page 47: ...set prescaler or output time values detected by processor 1 Data error in count values detected by processor 1 Press key 1 Press key 1 Press key 2 Check signal lines for possible noise sources 2 Check...

Page 48: ...CALER PRESETS OR OUTPUT TIME VALUES CAN BE VIEWED BUT NOT CHANGED 2 Check Front Panel Accessible Functions With Program Disable section of manual 1 Verify programming of Access parameters 1 Front pane...

Page 49: ...tion of the feed roll Each revolution equates to a linear distance of 2 feet The number of Display Units desired is 2 The Number of Pulses per Display Units is 48 When the number of Display Units and...

Page 50: ...13 3 2 B 9 10 6 8 7 USER INPUT 1 INPUT A INPUT USER B COMM DC OUT IN O3 SS O2 SS COMM USER O1 SS 12 AC 14 A RS 485 OPTION 4 5 AC 11 1 13 3 2 B 9 10 6 8 7 USER INPUT 1 INPUT A INPUT USER B COMM DC OUT...

Page 51: ...OUT AC DC AC DC 12 14 A RS 485 OPTION 4 5 11 1 13 3 2 B 9 10 6 8 7 USER INPUT 1 INPUT A INPUT USER B COMM O3 RLY O3 RLY O2 RLY O2 RLY O1 SS V IN SRC DC OUT AC DC AC DC INPUT 2 12 14 A RS 485 OPTION 4...

Page 52: ...7 C48CD017 2 Preset Counter w Prescaler Output Reflective LCD Yes No Yes N A C48CP005 C48CP015 2 Preset Counter Backlit LCD Yes No No N A C48CD100 C48CD110 2 Preset Counter Backlit LCD Yes No Yes N A...

Page 53: ...ounter Backlit LCD N A No Yes Yes O1 3 Preset Batch Counter Backlit LCD 85 to 250 VAC C48CB105 C48CB100 C48CB108 C48CB103 N A C48CB005 Yes No Yes 3 Preset Batch Counter Reflective LCD N A N A C48CB008...

Page 54: ...mer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a...

Page 55: ...C48C IM G 01 17 DRAWING NO LP0354...

Page 56: ...POE CUB4LP40 SLX 8ES 1 TORF1000 WF1000BF FANWAND721SMA FCOPPER SFP 100 PSDR060W SLX 5ES 1 309FXE ST 15 CRM000CMCMOD0000 CRM000CMDN000000 CR10001000000210 CR30001000000420 PAXDP000 NT24K 16M12 POE PT N...

Reviews: