Programming Keys:
- Selects Output being configured as indicated by the
number on the left side of the bottom display line.
- Selects Output Logic mode for selected Output
Reverse Annunciator Logic
This parameter controls the logic state of the Output
Annunciators (`01’, `02’, and `03’).
Programming Keys:
- Selects Output Annunciator being configured as
indicated by the number on the left side of the bottom
display line.
- Selects Output Annunciator Logic for selected Output
Output Power-Up State
This parameter controls the Power-Up State of the
Outputs
Programming Keys:
- Selects Output being configured as indicated by the
number on the left side of the bottom display line.
- Selects Output Power-up State for selected Output.
-24-
User Inputs
Up to three external User Inputs plus the front panel function key are
available on the C48 Counter/Batch Counter. The parameter list below shows
all available user input functions. The Input Pull-Up / Pull-down resistor and
Active logic level for all the User Inputs (except User Input B) are configured
with the Snk/Src jumper (See page 8). For User Input B (
), the Active
Logic Level is also configured with the Snk/Src jumper, however the input Pull-
Up / Pull-Down resistor is configured by DIP Switch position 4 (Input B `Snk/
Src’).
MODE
DESCRIPTION
Yes
; Output Annunciator Logic is Reversed.
Output Annunciator will be ON when the Output
is OFF.
No
; Output Annunciator Logic is not Reversed.
Output Annunciator will be ON when the Output
is ON.
MODE
DESCRIPTION
Off
; The output will be off at power-up.
On
; The output will turn on at power-up.
Previous State
; For latched output modes only.
The output will power-up in the state it was in at
power-down. For non-latched modes, the output
will power-up in the off state.
User Input State
Source
Sink*
Active
Vin > 3.5 VDC
Vin < 1.5 VDC
Vin < 1.5 VDC
InActive
Vin < 1.5 VDC
Vin > 3.5 VDC
Vin > 3.5 VDC
Input Voltage Level for Jumper Position
MODE
DESCRIPTION
Store
; When the user input is activated, the main display will `freeze’
and remain frozen until user input is released. On Batch Counter
Models, the unit will change to, and freeze the Counter 1/Counter 2
display. See Note 1.
Store&Reset
(Level Active Reset); When the user input is activated,
the count display will freeze and the internal Counter value (Counter 2
on Batch Model) will reset. The count value will be frozen and internally
held reset as long as the user input is held active. On Batch Counter
Models, the unit will change to, and freeze the Counter 1/Counter 2
display. See Note 1.
Reset Counter 2
(Level Active) [Batch model Only]; When the user
input is activated, the Counter 2 value and outputs will reset and be
held reset until user input is released.
Reset
(Edge Triggered); When the user input is activated, the counter
(1) value and outputs will be momentarily reset and then continue to
count and activate while input is held active.
Reset
(Level Active); When the user input is activated, the counter (1)
value and outputs will be reset and held reset until user input is
released.
Store&Reset
(Edge Triggered Reset); When the user input is
activated, the display will freeze and be held until the user input is
released. The internal Counter value (Counter 2 on Batch Model) will
reset momentarily and then continue to count while input is held active.
See Note 1.
Count Inhibit (SNK or SRC)
* Factory Setting