Note 1: Only one user input may be programmed for a Store (
) or Store
& Reset (
or
) function.
User Input 1
User Input 1 can be programmed for any of the
parameters listed above. Only User Input 1 may be
programmed for the Inhibit function.
-25-
User Input 2
User Input 2 can be programmed for any of the
parameters listed previously except for the Inhibit function.
User Input 2 is not available on the Batch Model with relay
outputs.
User Input B
User Input B is available when the Count Input (
)
parameter is set to `
’ or `
’. This input can be
programmed for any of the parameters listed previously
except for the Inhibit function.
User F1 Key
User F1 is the front panel function key. This user input
can be programmed for any of the parameters listed
previously except for the Inhibit and Program Disable
functions.
Programming / Protected Parameter
Menu Code Value (0-199)
The Programming Code value can be used to provide
Data Value or Programming Menu security. Depending on
the Code range selected and the Program Disable Level, it
may be necessary to enter the code value before the unit
allows access to Programming Menus or Protected Values.
See Front Panel Accessible Functions With Program
Disable, page 14, for more information.
MODE
DESCRIPTION
Reset Outputs
(Edge Triggered); When the user input is activated, all
active outputs will reset to their inactive states. This is a momentary
reset.
Reset All
(Level Active) [Batch model Only]; When the user input is
activated, the Counter 1 and Counter 2 values and outputs will reset
and be held reset until user input is released.
Change Display
(edge triggered); When the user input is activated,
the secondary display will sequence to the next available value.
Reset All
(Edge Triggered) [Batch Counter Only]; When the user input
is activated, the Counter 1 and Counter 2 value and outputs will be
momentarily reset and then continue to count and activate while input
is held active.
DESCRIPTION
0
Programming is Disabled and Code entry display
is not available when Program is Disabled.
1-99
100-199
Programming Menu appears when code is
entered and unit is at 1st level program disable.
Reset Counter 2
(Edge Triggered) [Batch model Only]; When the user
input is activated, the Counter 2 value and outputs will be momentarily
reset and then continue to count and activate while input is held active.
Program Disable
[level active] (not available for F1 Key); See page 14
for details of Program Disable options.
Count Inhibit
[level active] (User Input 1 only); When User Input 1 is
activated, the Counter(s) will stop counting until User Input 1 is
released.
Print Request
[level active] (RS485 Option only); When the user input
is activated, the count, preset, prescaler values, as configured in the
Print Options (“PrnOPt”) parameter will be continually transmitted on
the RS485 terminals. See RS485 Serial Communications section.
Protected Parameter Menu appears when Code
is entered and unit is at 1st level program
disable.
CODE VALUE